Complete the following steps:
1. Perform a virtual reseat or AC cycle the server.
2. If the problem persists, collect Service Data logs and contact Lenovo Support.
Note: The solution for this error may involve a system board replacement. If TPM encryption has
been enabled, back up TPM Encryption Recovery Key.
• FQXSFMA0052I: DIMM [arg1] has been disabled due to the error on DIMM [arg2].[arg3]
Severity: Info
Parameters:
[arg1] DIMM Silk Label, 1-based
[arg2] DIMM Silk Label, 1-based
[arg3] DIMM info (S/N, FRU and UDI.), e.g. "739E68ED-VC10 FRU 0123456"
User Action:
Complete the following steps:
1. Power off the system and remove A/C power.
2. Reseat the DIMM in the slot specified by the event message.
3. Restore A/C power and power on the system.
4. If the problem persists, collect Service Data logs and contact Lenovo Support.
Note: The solution for this error may involve a system board replacement. If TPM encryption has
been enabled, back up TPM Encryption Recovery Key.
• FQXSFMA0065I: Multi-bit CE of DIMM [arg1] has been deasserted after performing post package
repair. DIMM identifier is [arg2].
Severity: Info
Parameters:
[arg1] DIMM Silk Label
[arg2] DIMM info (S/N, FRU and UDI)
User Action:
Information only; no action is required.
• FQXSFMA0076M: DIMM [arg1] is not supported, DIMM identifier is [arg2].
Severity: Warning
Parameters:
[arg1] DIMM slot silk label
[arg2] DIMM identifier consists of S/N, FRU and UDI, e.g. "739E68ED-VC10 FRU 0123456"
User Action:
Complete the following steps:
1. Power off the system and remove A/C power.
2. Check user manual for supported DIMM types and replace the DIMM specified by the message with
a supported one.
3. If the problem persists, collect Service Data logs and contact Lenovo Support.
176