4. If the problem persists, collect Service Data logs and contact Lenovo Support.
Note: The solution for this error may involve a system board replacement. If TPM encryption has
been enabled, back up TPM Encryption Recovery Key.
• FQXSFIO0014J: A bad option ROM checksum was detected for the device found at Bus [arg1]
Device [arg2] Function [arg3]. The Vendor ID for the device is [arg4] and the Device ID is [arg5]. The
physical slot number is [arg6].
Severity: Error
Parameters:
[arg1] Bus
[arg2] Device
[arg3] Function
[arg4] VID
[arg5] DID
[arg6] Instance number
User Action:
Complete the following steps:
1. If this PCIe device and/or any attached cables were recently installed, moved, serviced or upgraded.
Reseat adapter and any attached cables.
2. Move adapter to a different system slot, if available.
3. Check Lenovo Support site for any applicable service bulletin or UEFI or adapter firmware update
that applies to this error.
Note: It may be necessary to configure slot to Gen1 or to use special utility software so that adapter
firmware can be upgraded. Gen1/Gen2 settings can be configured via F1 Setup -> System Settings
-> Devices and I/O Ports ->PCIe Gen1/Gen2/Gen3 Speed Selection, or the OneCLI utility.
4. If the problem persists, collect Service Data logs and contact Lenovo Support.
Note: The solution for this error may involve a system board replacement. If TPM encryption has
been enabled, back up TPM Encryption Recovery Key.
• FQXSFIO0015I: IFM: System reset performed to reset adapters.
Severity: Info
User Action:
Information only; no action is required.
• FQXSFIO0016M: IFM: Reset loop avoided - Multiple resets not allowed.
Severity: Warning
User Action:
Complete the following steps:
1. Update all firmware (including adapter firmware) to the latest levels.
2. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFIO0017M: IFM: Error communicating with the XCC - IFM may not be deployed correctly.
Severity: Error