5. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0034M: DIMM [arg1] (UID: [arg2]) of Intel Optane DCPMM persistent memory interleave
set should be moved to DIMM slot [arg3] in sequence.
Severity: Warning
Parameters:
[arg1] DIMM Silk Label, 1-based
[arg2] DIMM UID
[arg3] Expected DIMM slot number
User Action:
Complete the following steps:
1. Collect XCC Service Data.
2. Power off system.
3. Details included in this error message will provide the correct location for that DCPMM.
4. Move the DCPMM to the correct location.
5. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0035M: Intel Optane DCPMM interleave set should have [arg1] DCPMMs, but [arg2]
DCPMMs are missing.
Severity: Warning
Parameters:
[arg1] Number of dimms in the interleave
[arg2] Number of lossed dimms
User Action:
Complete the following steps:
1. Collect XCC Service Data.
2. Power off system.
3. The following error message FQXSFMA0036M logs will provide the details which DCPMMs are
missing.
4. Find all missing DCPMMs of error message FQXSFMA0036M logs and install them in the correct
location.
5. If an error occurs, follow steps 1 and 4 to get details on new error message.
6. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0036M: DIMM [arg1] (UID: [arg2]) of Intel Optane DCPMM persistent memory interleave
set is missing.
Severity: Warning
Parameters:
[arg1] Missed DIMM Silk Label
[arg2] Missed DIMM UID
User Action:
Complete the following steps:
.