Lenovo 7X69 Manual page 168

Hide thumbs Also See for 7X69:
Table of Contents

Advertisement

3. Without qualified memory, speeds supported above industry standards will not be enabled.
4. Contact your Local Sales Representative or Authorized Business Partner to order qualified memory
to replace the unqualified DIMM(s).
5. After you install qualified memory and power up the server, check to ensure this informational event
is not logged again.
6. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0007I: [arg1] DIMM number [arg2] has been replaced. [arg3]
Severity: Info
Parameters:
[arg1] Unqualified/Non Lenovo
[arg2] DIMM Silk Label, 1-based
[arg3] DIMM info (S/N, FRU and UDI.), e.g. "739E68ED-VC10 FRU 0123456"
User Action:
Complete the following steps:
1. This event should be followed by a recent FQXSFMA0006I event denoting the server does have
unqualified memory installed.
2. Information only; no action is required.
• FQXSFMA0008I: DIMM [arg1] POST memory test failure has been recovered. [arg2]
Severity: Info
Parameters:
[arg1] DIMM slot silk label
[arg2] DIMM identifier consists of S/N, FRU and UDI, e.g. "739E68ED-VC10 FRU 0123456"
User Action:
Information only; no action is required.
• FQXSFMA0008M: DIMM [arg1] has failed the POST memory test. [arg2]
Severity: Error
Parameters:
[arg1] DIMM slot silk label
[arg2] DIMM identifier consists of S/N, FRU and UDI, e.g. "739E68ED-VC10 FRU 0123456"
User Action:
Complete the following steps:
1. If the DIMM configuration was changed prior to this failure verify that the DIMMs are installed in the
correct population sequence.
2. RESEAT the DIMM that failed POST memory test and the DIMMs on adjacent slots if populated. Boot
to F1 setup and enable the DIMM. Reboot the system.
3. Swap the DIMM from failure location to another known good location to see if the failure follow the
DIMM or DIMM slot.
4. If this problem was encountered during an XCC / UEFI update process:
a. Power cycle the system by removing power for a few seconds.
164
ThinkSystem SR860 Messages and Codes Reference

Advertisement