3. If DC LED is not lit, remove and reinstall power supply.
4. If error LED is lit, replace the power supply.
5. If problem still exist, please send system event log to Lenovo service for further investigation.
• FQXSPPW0063M: Sensor [SensorElementName] has transitioned to critical from a less severe
state.
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Voltage
SNMP Trap ID: 1
CIM Prefix: PLAT CIM ID: 0522
User Action:
Complete the following steps until the problem is solved:
1. Perform virtual system reseat or A/C power cycle.
2. If the error persists, remove A/C power and any recently installed components.
3. If the system successfully powers on, complete the following steps:
a. Check the Server Proven website (http://www.lenovo.com/us/en/serverproven/index.shtml) to
make sure that recently installed components are compatible with the system.
b. Inspect the previously installed components for physical damage and fix it.
c. If the system does not successfully power on or if this is not the first occurrence of this problem,
go to step 4.
4. If the system has stand-by power, collect Service Data logs.
5. Contact Lenovo Support.
• FQXSPPW0101J: Redundancy Degraded for [RedundancySetElementName] has asserted.
This message is for the use case when Redundancy Degraded has asserted.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Redundant Power Supply
SNMP Trap ID: 10
CIM Prefix: PLAT CIM ID: 0804
User Action:
Information only; no action is required
• FQXSPPW0104J: Non-redundant:Sufficient Resources from Redundancy Degraded or Fully
Redundant for [RedundancySetElementName] has asserted.
This message is for the use case when a Redundancy Set has transitioned from Redundancy Degraded or
Fully Redundant to Non-redundant:Sufficient.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Redundant Power Supply
SNMP Trap ID: 10