• FQXSPPW0001I: [PowerSupplyElementName] has been added to container
[PhysicalPackageElementName].
This message is for the use case when an implementation has detected a Power Supply has been added.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: PLAT CIM ID: 0084
User Action:
Information only; no action is required.
• FQXSPPW0002L: [PowerSupplyElementName] has Failed.
This message is for the use case when an implementation has detected a Power Supply has failed.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Power
SNMP Trap ID: 4
CIM Prefix: PLAT CIM ID: 0086
User Action:
Complete the following steps until the problem is solved:
1. Check the LED's on the PSU:
a. if AC LED is not lit, check power cord and input voltage.
b. if DC LED is not lit, remove and re-install power supply.
c. If Error LED (!) is lit amber, Contact Lenovo Support for replacement.
2. If problem persists, collect Service Data log and Contact Lenovo Support.
• FQXSPPW0003G: Failure predicted on [PowerSupplyElementName].
This message is for the use case when an implementation has detected a Power Supply failure is
predicted.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Power
SNMP Trap ID: 164
CIM Prefix: PLAT CIM ID: 0088
User Action:
1. Check power supply LEDs:
2. If AC LED is not lit, check power cord and input voltage.
3. If DC LED is not lit, remove and reinstall power supply.
4. If error LED is lit, replace the power supply.
• FQXSPPW0005I: [PowerSupplyElementName] is operating in an Input State that is out of range.