Unpacking and installing the device
3.2 Mounting the device
Electrocution risk when control cabinet is open
When you open the control cabinet, there may be a dangerous voltage at certain areas or
components.
Touching these areas or components can cause death or serious physical injury.
• Disconnect the control cabinet from the power supply before opening it.
• Ensure that the power to the control cabinet cannot be turned on accidentally.
Risk of physical injury
The device is too heavy to be mounted exclusively with the 19" brackets of the front panel.
The device may fall down, injure people and get damaged.
• Secure the device using additional measures. The mounting screws of the telescopic rails
• Use handles attached to the front to carry and lift the device.
Drill holes for telescopic rails
You can find the dimensions for the drill holes under "Dimension drawing for drill holes for
telescopic rails (Page 162)".
You can find detailed information on the telescopic rails under: "Technical specifications of
the telescopic rails (Page 157)".
56
DANGER
CAUTION
may not protrude more than 5 mm into the device.
Workstation SIMATIC IPC RW-545A Operating
Instructions, 08/2023, A5E52943278-AA