Current output (DC)
Noise emission
Pollution degree
Degree of protection
Dust protection
Safety
Protection class
Safety regulations
See also
Safety instructions on ambient and environmental conditions (Page 44)
Workstation SIMATIC IPC RW-545A
Operating Instructions, 08/2023, A5E52943278-AA
Power supply unit 850 W:
•
460 W = 460 J/s = 0.44 BTU/s
Power supply unit 700 W (2 modules, each 700 W, redundant):
•
300 W = 300 J/s = 0.28 BTU/s
Power supply unit 550 W:
•
+5 V/22 A; +3.3 V/25 A; 150 W are permitted in total
•
+12 V
/26 A; +12 V
/15 A
1
2
•
–12 V/0.1 A; +5 V
/2 A
aux
The total output of all voltages is max. 550 W.
Power supply unit 850 W:
•
+5 V/35 A; +3.3 V/20 A; in total, 200 W are allowed
•
+12 V/70 A
•
–12 V/0.1 A; +5 V
/2 A
aux
The total output of all voltages is max. 850 W.
Power supply unit 700 W (2 modules, each 700 W, redundant):
•
+5 V/20 A, +3.3 V/20 A; 130 W are permitted in total
•
+12 V
/58.3 A
1
•
-12 V/0.5 A; +5 V
/3 A
aux
The total output of all voltages is max. 700 W.
< 45 dB(A) according to DIN 7779
At 20 °C and in Windows idle mode, the result is 40 dB (A).
Device is designed for environments with pollution degree 2
•
IP 30 (front) with closed front door
•
IP 20 on the rear according to EN 60529
With front door closed: Filter class G2 EN 779; particles > 0.5 mm are 99% retained
Protection class I compliant with IEC 61140
•
IEC 61010-2-201
•
EN 61010-2-201
•
UL 61010-2-201
•
CAN/CSA C22.2 No 61010-2-201
Technical specifications
9.2 General technical specifications
143