Siemens SIMATIC IPC RW-545A Operating Instructions Manual page 113

Industrial pc workstation
Table of Contents

Advertisement

Requirement
• You know the important safety instructions under "Safety instructions on device and
system extensions (Page 47)".
• The device is fully disconnected from the line voltage, see "Switching off the device
(Page 74)".
• The device is equipped with the drive cage type A.
Procedure
1. Open the device. Be sure to follow the important instructions under "Open the device
(Page 93)".
2. Pull out both plugs ①.
3. Unlatch the backplane by firmly pressing on the latches ② in the direction of the arrow and
simultaneously pressing on the ejector ③.
4. Remove the unlatched backplane board ④ by turning it upwards from the brackets and
removing it from the drive cage.
5. Close the device.
Workstation SIMATIC IPC RW-545A
Operating Instructions, 08/2023, A5E52943278-AA
Expanding and assigning parameters to the device
7.6 Installing and removing drives