Device maintenance and repair
8.3 Removing and installing hardware
5. Put down the fan support as shown.
6. Bend the locking latches ② of the fan support slightly outwards and remove the fan from
the fan support.
7. Place the new fan in the fan support as shown.
8. Guide the fan cable through the cable outlet ③.
9. Finally, snap the new fan completely into place in the locking latches ②.
10.Mount the fan support on the drive cage (see above).
11.Connect the fan cable to the motherboard.
12.Close the device.
See also
Maintenance intervals (Page 125)
8.3.3

Changing the backup battery

Replace spent batteries promptly, see information under "Maintenance intervals (Page 125)".
Risk of explosion and release of harmful substances
Before replacing the backup battery, take note of the important safety instructions
regarding battery replacement under "General safety instructions (Page 37)".