Siemens SIMATIC IPC RW-545A Operating Instructions Manual page 28

Industrial pc workstation
Table of Contents

Advertisement

Product description
1.4 External design of the device
FAN
Fan status
HDD3 ALARM
HDD alarm in connection
with RAID and monitoring
HDD2 ALARM
software.
HDD1 ALARM
The number of the HDD
HDD0 ALARM
alarm corresponds to the
number of mounting
locations of drives, see "Drive
cage type A (Page 16)" and
"Drive cage type B
(Page 18)".
The numbering of the drives
with the "Intel® Optane™
Memory and Storage
Management" software
differs from this numbering.
See important note under
"Display of a defective drive
of an onboard RAID system
(Page 78)".
28
OFF
No error
RED
Possible causes:
OFF
RAID is OK
A RED LED is lit up
The associated drive is not OK
All RED LEDs are
RAID synchronization running, RAID is not OK
flashing
The hard disk newly integrated in case of
error is synchronized with an existing hard
disk.
All RED LEDs are lit
RAID is not OK
up
The faulty drive could not be localized by the
monitoring software. It may be possible to
detect the defective drive with the RAID
software.
You can find information under "RAID1
system (Page 78)"
Front fan faulty
The fan on the processor heat sink is
faulty
Fan on drive cage type A faulty
Fan of the power supply unit 550 W faulty
Workstation SIMATIC IPC RW-545A Operating
Instructions, 08/2023, A5E52943278-AA

Advertisement

Table of Contents
loading

Table of Contents