Climatic And Mechanical Environmental Conditions - Siemens SIMATIC IPC RW-545A Operating Instructions Manual

Industrial pc workstation
Table of Contents

Advertisement

Technical specifications

9.5 Climatic and mechanical environmental conditions

9.5
Climatic and mechanical environmental conditions
See the note in "Applicability of technical specifications (Page 141)".
Climatic ambient conditions
Temperature
Operation
Storage/transport
Relative humidity
Operation
Storage/transport
Atmospheric pressure
Operation
Storage/transport
Mechanical ambient conditions
Vibration
Operation
2
Storage/transport
Resistance to shock
Operation
2
Storage/transport
Special features
Quality assurance
The power loss of the expansion cards for power supply unit 850 W may be increased
1
from 80 W to 310 W if the additional power loss of 230 W is drawn from an actively
cooled expansion card (for example: high-end graphics card) that emits its waste heat
directly into the ambient air and not into the interior of the device.
The device must be free of any mechanical faults when disk drives are installed in the
2
removable trays.
See also
Installation options for drives with drive cage type A (Page 104)
Installation options for drives with drive cage type B (Page 114)
148
Tested according to IEC 60068-2-2; IEC 60068-2-1; IEC 60068-2-14
+0 °C to +40 °C
Gradient: ≤ 10 K/h; no condensation
The maximum permitted power loss of the expansion cards is:
For power supply unit 550 W: 80 W
For redundant power supply unit 700 W: 80 W
For power supply unit
This information relates exclusively to the additional power loss of the expansion
cards.
–20 °C up to +60 °C
Gradient: ≤ 20 K/h; no condensation
Tested according to IEC 60068-2-78; IEC 60068-2-30
0 to 31 °C: 5-85 %; decreasing linearly to 5-50 % at 40° C
5% up to 95% at 25 °C to 55 °C; no condensation
Gradient: ≤ 20 K/h; no condensation
1080 up to 689 hPa,
corresponds to an altitude of –1000 m to 3000 m
1080 up to 660 hPa,
Corresponds to an altitude of -1000 m to 3500 m
Tested according to IEC 60068-2-6; 10 cycles
20 to 58 Hz, Amplitude 0.015 mm; 58 to 200 Hz: 2 m/s
5 up to 8.51 Hz; amplitude 3.5 mm; 8.51 up to 500 Hz: 9.8 m/s
Tested in accordance with IEC 60068-2-27
Half-sine; 9.8 m/s
; 20 ms; 100 shocks per axis
2
Half-sine; 250 m/s
; 6 ms; 1000 shocks per axis
2
In accordance with ISO 9001
850 W: Up to 310 W
1
Workstation SIMATIC IPC RW-545A Operating
Instructions, 08/2023, A5E52943278-AA
2
2

Advertisement

Table of Contents
loading