15 Cable

15.3.9 J395 Cable

Max. cable length: 10m
Application: Optical communication cable
for wiring between drive units (outside panel)
for wiring between NC-drive units
Use when wiring outside of the panel with a cable of 10m or less.
[OPT]
Connector : LGP-Z0007PK
Recommended manufacturer :
HONDA TSUSHIN KOGYO
2-core cable (section with reinforced sheath)
2-core cable (section without reinforced sheath)
(Note 1) Binding the cables too tight with tie-wraps could result in an increased loss or a disconnection. Use a
cushioning material such as a sponge or rubber when bundling the cables and fix so that the cables do not
move. Recommended clamp material: CKN-13SP KITAGAWA INDUSTRIES.
(Note 2) Never bundle the cables with vinyl tape. The plasticizing material in the vinyl tape could cause the POF cable
to break.
(Note 3) Loop the excessive cable with twice or more than the minimum bending radius.
IB-1501269-J
OPT
OPT
1
2
Wire material : PFDU-CL1002-22E60VT
Recommended manufacturer : TORAY
Cable
368
OPT
OPT
1
2
Minimum bending radius: R
50mm
30mm