25 Setting the Position Switches

25.3 Canceling the Position Switch

Enter a position switch number to be canceled (#75*1) in "# ( )" and a slash in "DATA ( )" on the setting field, then press
the [INPUT] key. Axis name of the specified position switch will be deleted, and the position switch is disabled. However,
the data in <dog1> and <dog2> are still retained in a memory. To enable the position switch again, only an axis name is
required for setting.