Connecting I/O Device Via Cc-Link Ie Field - Mitsubishi M800S Series Connection And Set Up Manual

Hide thumbs Also See for M800S Series:
Table of Contents

Advertisement

M800S/M80/E80 Series Connection and Setup Manual
7 Connection of Control Unit

7.12.3 Connecting I/O Device via CC-Link IE Field

The expansion unit FCU8-EX564 functions as a master station or slave (local) station of CC-Link IE Field. Connect the
CC-Link IE Field-compatible equipment with an ethernet cable (category 5e or above and twisted pair shield cable).
For details, refer to "M800/M80 Series CC-Link IE Field (Master/local) Specifications manual".
Option relay unit
(FCU8-EX70x)
CC-Link IE Field unit
(FCU8-EX564)
[Noise countermeasures of ethernet cable]
When the CC-Link IE Field unit is being used, expose the cable by removing a part of the cable sheath and make
sure to use the shield clamp for the exogenous noise countermeasure.
When you cannot use the shield clamp, make sure to install a ferrite core as a substitute to ethernet cable (near the
expansion unit).
<Related item>
Shield clamp fitting: "EMC Installation Guidelines: EMC Countermeasure Parts: Shield Clamp Fitting"
Ferrite core: "EMC Installation Guidelines: EMC Countermeasure Parts: Ferrite Core"
IB-1501269-J
CC-Link IE Field-compatible equipment
Ethernet cable
(category 5e or above and
twisted pair cable with shield)
Connector for
CC-Link IE Field
communication
Ethernet cable
Shield
Switching hub
Slave station
256
Slave station
Slave station
(* Prepared by MTB)

Advertisement

Table of Contents
loading

This manual is also suitable for:

M80 seriesE80 seriesM80w series

Table of Contents