(1) Select [Time] on the Monitr screen.
(2) Select [Time setting] on the integrated time screen.
The time setting mode is entered. The cursor appears at the "#1 Date" position in the Run-out time display.
(3) Set the date and time to "#1 Date" and "#2 Time" respectively.
(4) Select [Selfdia] on the diagn screen.
(5) Select [Battery clear] on the self diagn screen, and set the battery used years to "0".
(Note)
If battery used years is not cleared, passed years from default date (2014/4/1) will be displayed on battery
used years.