15 Cable

15.2.13 J100 Cable

Max. cable length: 20m
Application: Skip
[SKIP]
Connector
: 10120-3000PE
Case
: 10320-52F0-008
Recommended manufacturer : 3M
(Note 1) Fold the cable shield over the sheath, and wrap copper foil tape over it. Connect the wound copper foil
tape to GND plate of the connector.
(Note 2) When using the jackscrew M2.6-type 10320-52A0-008 for the shell, do not fasten the screws too tightly
otherwise the connector and the PCB may be damaged.
(Manufacturer recommended tightening torque: 0.20±0.05Nꞏm)
SKIP
SKIP
1
COM
11
COM
2
SKIP0
12
SKIP1
3
SKIP2
13
SKIP3
5
COM
COM
15
SKIP4
7
17
SKIP5
8
SKIP6
SKIP7
18
FG
Wire material :
UL2464 U-TKVVBS AWG24 × 6P
Recommended manufacturer :
Tachii Electric Wire
COM
COM
SK0
SK1
SK2
SK3
COM
COM
SK4
SK5
SK6
SK7
Crimp terminal
Recommended manufacturer : JST
353