Lenovo 7Y45 Instructions Manual page 58

Messages and codes reference
Hide thumbs Also See for 7Y45:
Table of Contents

Advertisement

• FQXSPFW2002I: The System [ComputerSystemElementName] has recovered from a firmware
hang.
This message is for the use case when an implementation has recovered from a System Firmware Hang.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0187
User Action:
Information only; no action is required.
• FQXSPIO0001L: The connector [PhysicalConnectorElementName] has encountered a
configuration error.
This message is for the use case when an implementation has detected an Interconnect Configuration
Error.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0266
User Action:
Complete the following steps until the problem is solved:
1. Make sure USB cable from front I/O module to system board is securely connected.
2. Replace the front operator panel if the problem still exist.
• FQXSPIO0003N: A diagnostic interrupt has occurred on system [ComputerSystemElementName].
This message is for the use case when an implementation has detected a Front Panel NMI / Diagnostic
Interrupt.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Other
SNMP Trap ID: 50
CIM Prefix: PLAT CIM ID: 0222
User Action:
1. If the NMI button on the operator information panel has not been pressed, complete the following
steps:
2. Make sure that the NMI button is not pressed.
3. Contact Lenovo for further support.
• FQXSPIO0004L: A bus timeout has occurred on bus [SensorElementName].
This message is for the use case when an implementation has detected a Bus Timeout.
Severity: Error
Serviceable: Yes
54