Table 2. Events organized by severity (continued)
Message String
Event ID
FQXSPBR4003I
Platform Watchdog Timer expired for [arg1].
FQXSPBR4007I
Management Controller [arg1]: Configuration restoration from a file by
user [arg2] failed to complete from [arg3] at IP address [arg4].
FQXSPBR4008I
Management Controller [arg1]: Configuration restoration from a file by
user [arg2] failed to start from [arg3] at IP address [arg4].
FQXSPCA0002M
Numeric sensor [NumericSensorElementName] going low (lower
critical) has asserted.
FQXSPCA0009M
Numeric sensor [NumericSensorElementName] going high (upper
critical) has asserted.
FQXSPCA0011N
Numeric sensor [NumericSensorElementName] going high (upper
non-recoverable) has asserted.
FQXSPCA0017M
Sensor [SensorElementName] has transitioned to critical from a less
severe state.
FQXSPCA0019N
Sensor [SensorElementName] has transitioned to non-recoverable
from a less severe state.
FQXSPCR0001N
Sensor [SensorElementName] has transitioned to non-recoverable
from a less severe state.
FQXSPIO0001L
The connector [PhysicalConnectorElementName] has encountered a
configuration error.
FQXSPIO0003N
A diagnostic interrupt has occurred on system
[ComputerSystemElementName].
FQXSPIO0004L
A bus timeout has occurred on bus [SensorElementName].
FQXSPIO0006N
A software NMI has occurred on system
[ComputerSystemElementName].
FQXSPIO0011N
An Uncorrectable Error has occurred on [SensorElementName].
FQXSPIO0015M
Fault in slot [PhysicalConnectorSystemElementName] on system
[ComputerSystemElementName].
FQXSPMA0005N
Subsystem [MemoryElementName] has insufficient memory for
operation.
FQXSPMA0012M
An Over-Temperature Condition has been detected on the
[PhysicalMemoryElementName] on Subsystem
[MemoryElementName].
FQXSPMA4035M
Health of DIMM [arg1] is in error state and sub-state is [arg2].
FQXSPOS4002I
Watchdog [arg1] Failed to Capture Screen.
FQXSPOS4003I
Platform Watchdog Timer expired for [arg1].
FQXSPOS4010I
OS Crash Video Capture Failed.
FQXSPPU0001N
An Over-Temperature Condition has been detected on
[ProcessorElementName].
FQXSPPU0007N
CPU voltage mismatch detected on [ProcessorElementName].
FQXSPPW0002L
[PowerSupplyElementName] has Failed.
Severity
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
Error
.