Alert Category: Critical - Power
SNMP Trap ID: 4
CIM Prefix: PLAT CIM ID: 0086
User Action:
Complete the following steps until the problem is solved:
1. Check the LED's on the PSU:
a. if AC LED is not lit, check power cord and input voltage.
b. if DC LED is not lit, remove and re-install power supply.
c. If Error LED (!) is lit amber, Contact Lenovo Support for replacement.
2. If problem persists, collect Service Data log and Contact Lenovo Support.
• FQXSPPW0003G: Failure predicted on [PowerSupplyElementName].
This message is for the use case when an implementation has detected a Power Supply failure is
predicted.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Power
SNMP Trap ID: 164
CIM Prefix: PLAT CIM ID: 0088
User Action:
1. Please ensure the PSU wattage, PSU efficiency level and the power supply unit is supported for the
system. Check power supply LEDs:
2. If AC LED is not lit, check power cord and input voltage. once the problem still exist, then replace the
power supply. If power supply model is no AC LED, then please power off the system then reseat
PSU and reboot system
3. If problem still exist, please send system event log to Lenovo service for further investigation.
• FQXSPPW0005I: [PowerSupplyElementName] is operating in an Input State that is out of range.
This message is for the use case when an implementation has detected a Power Supply that has input out
of range.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: PLAT CIM ID: 0098
User Action:
Please check system spec to ensure the configuration is within spec.
• FQXSPPW0006I: [PowerSupplyElementName] has lost input.
This message is for the use case when an implementation has detected a Power Supply that has input
that has been lost.
Severity: Warning
Serviceable: No
Automatically notify Support: No