• FQXSPPW0057J: Sensor [SensorElementName] has transitioned from normal to non-critical state.
This message is for the use case when an implementation has detected a Sensor transitioned to non-
critical from normal.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
Alert Category: Warning - Power
SNMP Trap ID: 164
CIM Prefix: PLAT CIM ID: 0520
User Action:
1. Please ensure the PSU wattage, PSU efficiency level and the power supply unit is supported for the
system. Check power supply LEDs:
2. If AC LED is not lit, check power cord and input voltage. once the problem still exist, then replace the
power supply. If power supply model is no AC LED, then please power off the system then reseat
PSU and reboot system
3. If problem still exist, please send system event log to service for further investigation.
• FQXSPPW0061M: Sensor [SensorElementName] has transitioned to critical from a less severe
state.
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Power
SNMP Trap ID: 4
CIM Prefix: PLAT CIM ID: 0522
User Action:
1. Please ensure the PSU wattage, PSU efficiency level and the power supply unit is supported for the
system. Check power supply LEDs:
2. If AC LED is not lit, check power cord and input voltage. once the problem still exist, then replace the
power supply. If power supply model is no AC LED, then please power off the system then reseat
PSU and reboot system
3. If problem still exist, please send system event log to service for further investigation.
• FQXSPPW0063M: Sensor [SensorElementName] has transitioned to critical from a less severe
state.
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Voltage
SNMP Trap ID: 1
CIM Prefix: PLAT CIM ID: 0522
User Action:
Complete the following steps until the problem is solved:
.