Complete the following steps:
1. Replace any hard disk drive that is indicated by lit status.
2. Recreate the array.
3. Restore the date from backup.
• FQXSPSD0007I: Rebuild in progress for Array in system [ComputerSystemElementName].
This message is for the use case when an implementation has detected that an Array Rebuild is in
Progress.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: PLAT CIM ID: 0178
User Action:
Information only; no action is required.
• FQXSPSD2000I: The [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName].
This message is for the use case when an implementation has detected a Drive has been Removed.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: PLAT CIM ID: 0163
User Action:
Information only; no action is required.
• FQXSPSD2001I: The [StorageVolumeElementName] has recovered from a fault.
This message is for the use case when an implementation has detected a Drive was Enabled.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Hard Disk drive
SNMP Trap ID: 5
CIM Prefix: PLAT CIM ID: 0167
User Action:
Information only; no action is required.
• FQXSPSD2002I: Failure no longer Predicted on [StorageVolumeElementName] for array
[ComputerSystemElementName].
This message is for the use case when an implementation has detected an Array Failure is no longer
Predicted.
Severity: Info
Serviceable: No
Automatically notify Support: No