Code
E65
CLEAN FLOAT SWITCH – XXX F OR XXX C
E66
DRAIN VALVE OPEN – XXXF OR XXXC
E67
SYSTEM INTERFACE BOARD NOT CONFIGURED
- CALL SERVICE
E68
OIB FUSE TRIPPED – CALL SERVICE
E69
RECIPES NOT AVAILABLE – CALL SERVICE
E70
OQS TEMP HIGH
E71
OQS TEMP LOW
E72
TPM RANGE LOW
E73
TPM RANGE HIGH
E74
OQS ERROR
E75
OQS AIR ERROR
E76
OQS ERROR
E85
LEFT RETURN VALVE NOT OPEN - FILTRATION
DISABLED - CALL SERVICE
E86
LEFT RETURN VALVE NOT CLOSED -
FILTRATION DISABLED - CALL SERVICE
E87
RIGHT RETURN VALVE NOT OPEN - FILTRATION
ERROR MESSAGE
The float switch does not detect oil.
Ensure the float switch moves freely up and
down.
Drain valve is opened during cooking.
Controller is turned on when the SIB board
is not configured. Call service.
The VIB board OIB fuse has tripped and
didn't reset. Call service.
The controller has not been programmed
with product recipes. Replace controller
with factory programmed controller.
Oil temperature is too high for a valid OQS
reading. Filter at a temperature between
300ºF (149ºC) and 375ºF (191ºC).
Oil temperature is too low for a valid OQS
reading. Filter at a temperature between
300ºF (149ºC) and 375ºF (191ºC).
The TPM is too low for a valid OQS reading.
This may also be seen with fresh new oil.
The incorrect oil type may be selected in
the setup menu. The sensor may not be
calibrated for the oil type. See oil type chart
in instruction document 8197316. If issue
continues contact a FAS.
The TPM reading is too high for a valid OQS
reading. Dispose the oil.
The OQS has an internal error. If issue
continues contact a FAS.
The OQS is detecting air in the oil. Check
the O-rings and check/tighten prescreen
filter to ensure no air is entering the OQS
sensor. If issue continues contact a FAS.
The OQS sensor has a communication
error. Check connections to the OQS
sensor. Power cycle the entire fryer battery.
If issue continues contact a FAS.
Left return valve was trying to open, and
confirmation is missing
Left Return valve was trying to close, and
confirmation is missing
Right return valve was trying to open, and
5-10
EXPLANATION
1. Ensure the frypot is full of
oil.
2. Float switch may be stuck up
or down.
3. Clean the float switch.