2. Frymaster recommends that the minimum distance from the flue outlet to the bottom edge of the
hood be 24 in. (600 mm) when the appliance consumes more than 120,000 BTU per hour.
3. Test the fryer electrical system:
a. Plug the fryer electrical cord(s) into a grounded electrical receptacle.
b. Place the power switch in the ON position.
Verify that the display indicates the controller is on.
c. Place the fryer power switch in the OFF position. Verify that the display indicates OFF.
4. Refer to the data plate on the inside of the fryer door to determine if the fryer burner is
configured for the proper type of gas before connecting the fryer quick-disconnect device or
piping from the gas supply line.
Fryers MUST be connected ONLY to the gas type identified on the attached rating plate.
5. Verify the minimum and maximum gas supply pressures for the type of gas to be used in
accordance with the accompanying tables and the data plate on the inside of the fryer door.
Non- CE Standard for Incoming Gas Pressure
Fryer Model
Gas Type
Nat
Incoming Min
6/1.49/14.93
Pressure
W.C/kpa/mbar
Incoming Max
14.00/3.48/34.84
Pressure
W.C/kpa/mbar
Burner Mani-
4.0/1.0
fold Pressure
WC/kpa
Orifice Size
2.26
(mm)
(1) mbar = 10,2 mm H2O
CE Standard for Incoming Gas Pressure
Fryer
FQG80T
Model
Gas Type
G20
G25
Natu-
Natural
ral
Gas
Gas
Gro-
Lacq
nique
Incoming
20
20
Min Pres-
sure
(mbar)
Incoming
25
25
Max
Pressure
(mbar)
Burner
7
10
Manifold
Pressure
(mbar)
Orifice
2.26
2.26
Size (mm)
(1) mbar = 10,2 mm H2O
FQG80T
LP
11/2.74/27.37
6/1.49/14.93
14.00/3.48/34.84
14.00/3.48/34.84
10.0/2.5
3.20/0.80
1.40
2.20
FQG100T
G30
G31
G20
Butane
Pro-
Natural
/Propa
pane
Gas
ne
Lacq
28/30
37
20
50
50
25
17
20.6
10
1.40
1.40
2.20
DANGER
FQG100T
Nat
LP
11/2.74/27.37
14.00/3.48/34.84
8.25/2.5
1.40
G25
G30
G31
Natural
Butane
Pro-
Gas
/Propa
pane
Gro-
ne
nique
20
28/30
37
25
50
50
10
23.9
23.9
2.20
1.40
1.40
2-6
FQG120T
Nat
6/1.49/14.93
11/2.74/27.37
14.00/3.48/34.84
14.00/3.48/34.84
4.0/1.0
10.0/2.5
2.04
1.30
FQG120T
G20
G25
G30
Natu-
Natural
Butane
ral
Gas
/Propa
Gas
Gro-
ne
Lacq
nique
20
20
28/30
25
25
50
10
10
23.9
2.04
2.04
1.95
LP
G31
Pro-
pane
37
50
23.9
1.95

Advertisement