4. Replace the filter leaf assembly in the filter pan, en-
suring that the filter pick up tube is lowered and se-
curely mounted into the brackets in the filter pan
(see Figure 3).
5. Push the filter pan back into the fryer, positioning it
all the way to the back of the cabinet. Ensure "P" is
NOT displayed on the controller. The filtration system
is now ready for use
Figure 4
Do not drain more than one frypot at a time into the built-in filtration unit to avoid
overflow and spillage of hot oil that may cause severe burns, slipping and falling.
The filter pan must be emptied and cleaned at the end of frying operations each day.
Some food particles can spontaneously combust if left soaking in certain shortening ma-
terial.
Do not bang fry baskets or other utensils on the fryer's joiner strip. The strip is present
to seal the joint between the fry vessels. Banging fry baskets on the strip to dislodge
shortening will distort the strip, adversely affecting its fit. It is designed for a tight fit
and should only be removed for cleaning.
The filter pump is equipped with a manual reset switch in case the filter motor over-
heats, or an electrical fault occurs. If this switch trips, turn off power to the filter sys-
tem and allow the pump motor to cool 20 minutes before attempting to reset the switch
(see Figure 4).
Use caution and wear appropriate safety equipment when resetting the filter pump re-
set switch. Resetting the switch must be accomplished with care to avoid the possibility
of a burn.
Figure 3
DANGER
DANGER
WARNING
WARNING
WARNING
3-7