Download Print this page

Frymaster FilterQuick easyTouch FQG100T Installation, Operation And Maintenance Manual page 48

Hide thumbs Also See for FilterQuick easyTouch FQG100T:

Advertisement

PROBLEM
Auto filtration won't
start.
Filter Pump runs,
but oil return is very
slow.
5.3.1 Incomplete Filtration
Should the auto filtration procedure fail an error message is generated. Follow the instructions on the
screen to return the oil and clear the error.
DISPLAY
IS VAT FULL?
FILLING IN PROGRESS
IS VAT FULL?
FILLING IN PROGRESS
IS VAT FULL?
CHANGE FILTER PAD?
REMOVE PAN
CHANGE FILTER PAD
PROBABLE CAUSES
A. Oil level too low.
B. Oil temperature is too low.
C. Filter Pan out.
D. Filtration in recipe settings is set
to OFF.
E. Filter relay has failed.
A. Clogged filter.
B. Improperly installed or prepared
filter pan components.
C. Pre-filter screen may be clogged
or not fully tightened.
1. Press the √ (check) button if the vat is full to continue.
The controller returns to idle cook mode or
vat is not filled completely.
2. No action required as the pump runs.
3. Press the √ (check) button if the vat is full to continue.
The controller returns to idle cook mode or
vat is not filled completely.
4. No action required as the pump runs.
5. Press the √ (check) button if the vat is full to continue.
The controller returns to idle cook mode or
vat is not filled completely. If this is the sixth consecutive
sequence of incomplete filtration skip to step 10.
6. Press the √ (check) button to continue. Pressing X
advances to
7. Remove the filter pan.
8. Change the filter pad and ensure the filter pan has been
CORRECTIVE ACTION
A. Ensure oil level is at the top oil
fill line (at the top oil level
sensor).
B. Ensure the oil temperature is at
setpoint.
C. Ensure
display P. Ensure the filter pan
is fully seated into fryer. Power
cycle the fryer.
D. Set filtration in recipes to ON.
E. Call your FAS for assistance.
A. Ensure the filter is not clogged.
If so, replace the filter.
B. Remove the oil from the filter
pan and replace the filter.
Verify, that the rough side of the
envelope is facing up.
Verify that O-rings are present
and in good condition on filter
pan connection fitting.
C. Clean pre-filter (see section 4.4.2)
and ensure it is tightened with
the attached wrench.
ACTION
.
5-6
controller
does
not
. Press X if
. Press X if
. Press X if

Advertisement

loading