7.6.8

Net Shooting Setting menu

The [Net Shooting Setting] menu sets up net shoot parameters. Selects [Net Shooting
Setting] on [Initial Setting] then push the left-click button.
Net Diameter: Sets net diameter in increments of 10 meters. Setting range is 200 m
to 1000 m.
Tilt Interlock: Turns on/off interlocking of diameter of net course mark with tilt angle.
Net Plot Corr-LYR1, 2, 3, 4, 5: The movement of the net during net shooting is plotted
using water current speed and direction fed from a current indicator. The current indi-
cator feeds that data for five depths (layers), thus net movement will be different at
each layer. Determine degree of difference among layers considering net, sea condi-
tions, etc. If 50% is set, for example, the net movement plot mark moves at speed of
50% of water current speed.
7.6.9

Stabilization menu

The [Stabilization] menu compensates for the affects of pitching and rolling. Select
[Stabilization] on Initial [Setting menu] then push the left-click button. Requires a iner-
tial measurement unit.
Stabilization: Turns stabilization on/off.
Note: The default function of the 9/F9 key turns stabilization on/off.
Pitch Angle Cor: Offsets the pitch angle error generated by the inertial measurement
unit.
Roll Angle Cor: Offsets the roll angle error generated by the inertial measurement
unit.
Sensor: Select the type of the inertial measurement unit used, FURUNO inertial mea-
surement unit or GPS gyro (satellite compass).