REPLACING DAMAGED DRAIN FITTING

The following procedure is for the field repair of a broken drain fitting.
1. Use a drill with a 1 7/8-inch (48 mm) hole saw to drill out the bottom
of the drain fitting.
Be sure to drill completely through fitting and bottom liner.
Do not use thread sealer on drain fitting.
2. Insert adapter into drain fitting. Do NOT use thread sealer on ABS
drain fitting.
If sealer is used the ABS drain fitting may crack or leak!
(Tee should be tightened no more than 4 turns.)
Do not over-tighten threads.
HUSSMANN CORPORATION • U.S. & CANADA 1-800-922-1919 • BRIDGETON, MO 63044-2483 • MEXICO 1-800-890-2900 • WWW.HUSSMANN.COM • PN 3181178_A