Medium Temperature Case Wiring Diagram - Hussmann INSIGHT REACH-IN Installation & Operation Manual

Use this manual along with insight door manual
Table of Contents

Advertisement

MEDIUM TEMPERATURE CASE WIRING DIAGRAM

COMPLETE CASE WIRING
This is the standard wiring diagram. See case serial plate and QR code (located on the serial plate) for
case-specific wiring options.
GN
BK
WT
WT
CASE INPUT POWER (120V)
9
10
11
12
WT WT
WT
FRAME A.S.
NOTES:
1. PRINTED DOCUMENT REQUIRED SETTING: ALL COLORS BLACK & WHITE
2. ALL WIRES 18 AWG UNLESS OTHERWISE NOTED
3. IRI - ABBREVIATION FOR INSIGHT REACH IN
4. DARK BLACK LINES IN TERMINAL BLOCKS REPRESENT REMOVABLE JUMPERS
5. LED POWER SUPPLIES ARE LOCATED ON SEPARATE COMPONENT TRAY IN RACEWAY
5.1. LED POWER SUPPLY TRAY IS LOCATED IN DOOR MODULE BOM
5.2. LED POWER SUPPLY TRAY IS TO BE INSTALLED IN DOOR FRAME AREA
5.3. FINAL ELECTRICAL CONNECTIONS TO BE MADE AFTER DOOR FRAME IS ATTACHED TO CASE
HUSSMANN CORPORATION • U.S. & CANADA 1-800-922-1919 • BRIDGETON, MO 63044-2483 • MEXICO 1-800-890-2900 • WWW.HUSSMANN.COM • PN 3181178_A
BK
13
14
15
16
BK
BK
BK
RACEWAY COMPARTMENT
GN
GN
HARNESS
0392398001
FANS
UL COLOR CODES / ABBREVIATIONS
6-9
REVISION HISTORY
REV
ECN
DATE
REVISION DESCRIPTION
A
ECN-NPD-0004922
2021/12/21
ISSUED FOR RELEASE
UPDATED TO REFLECT
B
ECN-NPD-0005428 2022/07/11
ELECTRICAL MODULE CHANGES
IN INSIGHT REACH IN
24 VDC
120-277VAC
120-277VAC
WT
WT
BK
BK
3117868 TRANSFORMER 96W
3117868 TRANSFORMER 96W
4 AND 5 DOOR ONLY
FACTORY 14GA WIRE
FACTORY 10GA WIRE
RED = RD
WHITE = WT
BLACK = BK
GREEN = GN
FIELD WIRE
BLUE = BL
BROWN = BN
YELLOW = YL
ORANGE = OR
GRAY = GY
VIOLET = VT
DO NOT SCALE DRAWING
SHEET 1 OF 4
REV BY CHKD BY APPR BY
BMK
SNAIK
CJS
BMK
SNAIK
CJS
BK
RD
BK
RD
24 VDC
TO LIGHTING
R
DIAGRAM-WIRING IRI
MED TEMP 2.0
P/N
REV
3159488