Drip Piping Lineup Arrangements; Installing Splashguards - Hussmann INSIGHT REACH-IN Installation & Operation Manual

Use this manual along with insight door manual
Table of Contents

Advertisement

DRIP PIPING LINEUP ARRANGEMENTS

The following illustrations below show typical arrangements for
installing drip pipes for a lineup of merchandisers. Illustrations are
for reference only. Piping may vary with location and access to hub
drain(s). Each merchandiser waste outlet must be individually piped to
a hub drain if 1/4 in. drip piping pitch cannot be maintained.
NOTE:
No more than two merchandiser are to be piped per water seal. Do
not install water seal between two merchandiser waste outlets that are
piped together. (Double water seals in series will cause an air lock and
prevent drainage.)
M
HUSSMANN CORPORATION • U.S. & CANADA 1-800-922-1919 • BRIDGETON, MO 63044-2483 • MEXICO 1-800-890-2900 • WWW.HUSSMANN.COM • PN 3181178_A

INSTALLING SPLASHGUARDS

The splashguard is shipped inside each merchandiser. After
merchandisers have been leveled and joined, and all drip piping,
electrical and refrigeration work has been completed, re-install the
front color panel, then install the splashguards.
First, position top of splashguard over the top edge of the bracket;
second, push the lower edge of the splashguard toward the bottom of
the bracket until it snaps into place.
SPLASH GUARD VIEW
Side view
Installing End Splashguard:
Front Splashguard
Place Splashguard End to the
inside of Splashguard front
3-3
Splashguard
Retaining
Bracket
End Splashguard