Optional Refrigerant Piping - Hussmann INSIGHT REACH-IN Installation & Operation Manual

Use this manual along with insight door manual
Table of Contents

Advertisement

OPTIONAL REFRIGERANT PIPING

Optional Connection Location:
The refrigerant line connections are at the right-hand end of
merchandiser (end opposite the main serial plate) beneath the display
pans. A sticker marks the location of the connection. The installer must
saw a hole to exit the cases.
A refrigeration shroud ships with each
case. Be fore making connections,
place the refrigeration shroud over
refrigeration piping so that when the
shroud is rotated, it will be upright.
The image at right shows the correct
orientation.
When making connections, be careful
not to burn, scorch, or overheat the
shroud. Once connections have been
made, apply silicone sealant to the
bottom of the shroud, as shown in
the image at right.
HUSSMANN CORPORATION • U.S. & CANADA 1-800-922-1919 • BRIDGETON, MO 63044-2483 • MEXICO 1-800-890-2900 • WWW.HUSSMANN.COM • PN 3181178_A
As shown in the image at right,
rotate and center the shroud over
the refrigeration outlet foam pad.
Seal this outlet thoroughly. Seal both the inside and the outside. We
recommend using an expanding polyurethane foam insulation. Cover
the foam with silicone to prevent water from entering the foam.
2-2