Installing The Waste Drain - Hussmann Multideck Meat 3750 Installation Manual

Table of Contents

Advertisement

Installation manual
Installing a Waste Drain
Each case must be connected to its own waste drain See figure 1: service layout for of the drain up-stand. The case is
supplied with the Ø40mm (outside diameter) PVC piping, drain trap and elbows
To install a waste drain:
1. Install PVC drain parts using recommended PVC cleaner, primer and cement per manufacturer's
recommendation.
2. Apply PVC specific threaded pipe sealer on the male threads of the plug.
3. Thread plug into adapter until snug, but not to exceed four (4) full rotations.
4. Installed drain piping may require additional support depending on the number and location of the hub floor
drains. The installer should always provide adequate support to all drain piping arrangements to prevent excess
stress on all drain piping components. The installer must provide additional support when "evac" type waste
water systems are applied.
5. Test for leakage by pouring water down the drain and ensure trap is primed before starting refrigeration.
6. NOTE: All joints to be glued with suitable adhesive.
_________________________________________________________________________________________________________________________
Page 15
NOTES
Drains must be connected to local
council requirements.
All joins must be solvent welded.
CAUTION
Incorrectly installed drain traps will result in
adverse air leaking into the case.
figure 17
drain trap orientation
MJPE multideck and SMD/SME Low Height Multideck