Control Register - Delta DVP01LC-SL Instruction Sheet

Load cell module

Advertisement

Available languages
  • EN

Available languages

Load cell module
Average value filter
Isolation method
Series connection to
DVP-PLC MPU
Operation / storage
temperature
Vibration / shock immunity
 Complying with DIN1319-1, the tolerance of measured value should be ≤ 0.05% under 20°C
+ 10K temperature range
 When the corrected ambient temperature and the actual temperature have a difference of
more than 10°C, it is suggested that you re-correct it.
 Control Register
CR#
Add.
Attrib.
#0
H1000 O
#1
H1001 O
#2
H1002 O R/W Eigenvalue
#3
H1003 O R/W
#6
H1006 X R/W Tare gotten from CH1
#7
H1007 O R/W Gross/Net weight
#8
H1008 O R/W
#9
H1009 O R/W
#10 H100A O R/W
#12 H100C X
#13 H100D X
Setting range: K1 to K100
500 VAC between digital circuits and Ground
500 VAC between analog circuits and Ground
500 VAC between analog circuits and digital circuits
Connectable to the left side of MPU, numbered from 100 to
107 according to the position of module from the closest to
farthest to MPU.
Operation: 0 to 55°C (temp.), 5 to 95% (humidity), pollution
degree 2
Storage: -25 to 70°C (temp.), 5 to 95% (humidity)
International standards: IEC61131-2, IEC 68-2-6 (TEST Fc)/
IEC61131-2 & IEC 68-2-27 (TEST Ea)
.
Register name
R
Model name
R
Firmware version
Reaction time for
measurement
Gross weight from CH1
(Low word)
Gross weight from CH1
(High word)
Average number of times
gotten from CH1
Weight gotten from CH1
R
(Low word)
Weight gotten from CH1
R
(High word)
Voltage output
Set up by the system:
DVP01LC-SL model code = H'4106
Displaying the current firmware version in
hex.
Mode 0 (H'0000): 1 mV/V
Mode 1 (H'0001): 2 mV/V, default
Mode 2 (H'0002): 4 mV/V
Mode 3 (H'0003): 6 mV/V
Mode 0 (H'0000): 2 ms
Mode 1 (H'0001): 10 ms
Mode 2 (H'0002): 20 ms
Mode 3 (H'0003): 40 ms
Mode 4 (H'0004): 80 ms, default
Mode 5 (H'0005): 200 ms
Mode 6 (H'0006): 380 ms
Reading the present average value as
tare
bit0: CH1
Taking the present weight as the gross
weight (K0) or the net weight (K1).
Users can input the value or use the
instruction to read the gross weight.
Default: 0
Default: K10; Range: K1~K100
If the setting value exceeds the range, it
will be automatically changed to K1 or
K100.
Displaying the weight.
Default: K0
Displaying the weight.
Default: K0