Pentair Fleck 3150 NXT Installer Manual page 121

Hide thumbs Also See for Fleck 3150 NXT:
Table of Contents

Advertisement

1. Set the relay Start time #2 with
2. Can be adjusted from: end time #1 +1 to the total regeneration
duration minus 1 minute;
3. Press
to validate the selection and advance to the next
parameter;
4. Set the relay End time #2 with
5. Can be adjusted from: start time #2 + 1 to the total
regeneration duration;
6. Press
to validate the selection and advance to the next
parameter.
Volume based (Chemical pump)
Activate the relay output during the service for a preset duration based upon the volume of treated
water.
Info
Only visible for metered systems if "volume based" was selected as auxiliary in the
previous step.
This parameter has two steps.
The first one determines the volume which activates the relay.
The second one determines how long the relay has to be activated once the programmed
volume has passed.
1. Set the relay activation volume with
2. Can be adjusted from: 1L to the total capacity of a service
cycle;
3. Press
to validate the selection and advance to the next
parameter;
4. Set the relay activation duration with
5. Can be adjusted from: 1 to 7200 seconds;
6. Press
to validate the selection and advance to the next
parameter.
6.2.5.29 Push settings
Push master programming settings of the unit to all other connected units.
Ref. MKT-IM-010 / F - 16.01.2023
Installer manual Fleck 3150 NXT/NXT2 - Programming
and
;
and
;
,
and ;
,
and ;
Activated 12 minutes after
the regeneration started.
TIME BASED - START
TIME #2.
Deactivated 150 minutes
after the regeneration
started.
TIME BASED - END
TIME #2.
Activates upon 1 L.
VOLUMEBASED-VOLUME-L.
Deactivates upon
10 seconds.
VOLUMEBASED-DURATION-
S.
121 / 190