Installer manual Fleck 3150 NXT/NXT2 - Programming
Info
Only visible in system 14, and on master valve, identified by
screen.
Depending on the number of tanks used in the system, there might up to 7 trip point to
set up (for 8 tanks systems).
Each additional trip point might be set for a flow rate equal to the previous one plus 1 l/
min.
1. Set the trip point flow rate with
ð Can be adjusted from 1 to 7569 l/min;
2. Press
to validate the selection and advance to the next
parameter;
3. Set the trip point service duration with
ð Can be adjusted from 1 to 90 seconds;
4. Press
to validate the selection and advance to the next
parameter;
5. Set the trip point service standby with
ð Can be adjusted from 60 to 300 seconds;
6. Press
to validate the selection and advance to the next
parameter.
6.2.5.10 Valve type
Select which valve is being used with the NXT2.
Options:
• 2510;
• 2750 (default);
• 2850;
• 2900/2910;
• 3150;
• 3900;
• 2815.
1. Set valve type at 3150 with
2. Press
to validate the selection and advance to the next
parameter.
6.2.5.11 Regeneration flow
Set the direction of flow during the brine draw cycle for softener, or set filter.
Options:
108 / 190
,
and ;
and
;
and
;
and
;
on the controller
Example: trip point #1.
Ref. MKT-IM-010 / F - 16.01.2023