Pentair Fleck 3150 NXT Installer Manual page 102

Hide thumbs Also See for Fleck 3150 NXT:
Table of Contents

Advertisement

Installer manual Fleck 3150 NXT/NXT2 - Programming
Parameter
METER TYPE
0.75" PADDLE
0.75" TURBINE
1.0" TURBINE
1.25" TURBINE
1.5" TURBINE
PULSES/L
MAXIMUM FLOW -
LPM
CONTINUOUS
FLOW DETECT
CONTINUOUS
FLOW DETECT -
FLOW RATE- LPM
CONTINUOUS
FLOW DETECT -
DURATION
AUXILIARY 1
ALARM BASED
CYCLE BASED
102 / 190
Options
GENERIC
(default for 2510)
1.0" PADDLE
(default for 2750)
1.5" PADDLE
(default for 2815 and
2.0" PADDLE
(default for 2910 and
3.0" PADDLE
(default for 3900)
0 to 1500
76 to 7570
ON
OFF
0.1 to 227.1
1 to 255
STANDBY
OFF
TIME BASED
VOLUME
BASED
Definition
-
Default flow meter type is based on
the valve type;
This screen will only display when
-
regeneration type selected is
softener meter immediate or
delayed.
-
-
2850)
-
3150)
PULSES/L
Only displayed if "Generic" is
chosen for the meter type.
l/min
Even if maximum theoretical
programmable value is 9999 or
999.9 (depending on the unit), the
controller will consider only up the
value listed in the side column.
-
This screen will only display when
regeneration type selected is
(default)
softener meter immediate or
delayed.
l/min
Only displayed if continuous flow
detect is ON.
Even if maximum theoretical
programmable value is 99999.9 l/
min, the controller will consider
only up to 227.1 l/min.
Hour
Only displayed if continuous flow
detect is ON.
Activates relay from beginning of
regeneration and during standby
phase.
(default)
-
-
Any alarm or error detected by the
controller will start signal output
from Auxiliary relay#1.
-
-
-
-
This choice will only available
when metered regeneration type.
Note
Ref. MKT-IM-010 / F - 16.01.2023