1. Adjust the cycle time with
ð Can be adjusted from: 0 to 240 minutes;
2. Press
to validate the selection and advance to the next
parameter;
3. Repeat for each cycle.
6.2.5.26 Meter type
Select the size of the flow meter.
Info
Available only for softening metered systems.
Options:
• 0.75" paddle (standard for 2510 valve series);
• 0.75" turbine;
• 1.0" paddle (standard for 2750 valve series);
• 1.0" turbine;
• 1.25" turbine;
• 1.5" paddle (standard for 2815 and 2850 valve series);
• 1.5" turbine:
• 2.0" paddle (standard for 2900 and 3150 valve series);
• 3.0" paddle (standard for 3900 valve series);
• generic.
Ref. MKT-IM-010 / F - 16.01.2023
and
;
Installer manual Fleck 3150 NXT/NXT2 - Programming
1. Backwash: 10 min
(default).
2. Draw: 60 min (default).
3. Rapid rinse: 10 min
(default).
4. Tank Refill: 12 min
(default).
5. Pause: 0 min, (not used,
default).