Installer manual Fleck 3150 NXT/NXT2 - Programming
Mandatory
For a timeclock valve, this value must be set !
Info
For metered valves, calendar override parameter would trigger a regeneration only if
the volumetric control did not start a regeneration before calendar override period
elapsed.
Each volumetric regeneration happening reset the calendar override delay.
1. Adjust the number of days with
2. Press
to validate the selection and advance to the next
parameter.
ð Can be adjusted from:
1 to 99 days for timeclock regeneration;
OFF to 99 days for metered regeneration.
6.1.4.5
Regeneration start time
Set the time for regeneration start.
Mandatory
Must be set when the regeneration flow programmed is timeclock, metered delayed or
when a calendar override is set !
1. Adjust the time of regeneration with
2. Press
to validate the selection and return to service.
6.1.5
Master programming mode
Info
As soon as programming mode is entered, all parameters can be displayed or set to
suit the needs.
Depending on the current programming, some functions will not be displayed or will not
be selectable.
72 / 190
,
and
.
,
and
.
Without calendar override.
override every 3 days.
Regeneration at 2:00 am.
Ref. MKT-IM-010 / F - 16.01.2023