6.2.5.19 Remote regeneration
Select the regeneration type for remotely started regeneration (external dry contact input, see
chapter NXT2 controller connections [
Info
This mode can be combined with the other methods of regeneration
The remotely started regenerations overrule the other regeneration type once the signal
is acquired.
Options:
• off (default);
• immediate;
• delayed.
1. Set the remote regeneration mode with
2. Press
to validate the selection and advance to the next
parameter.
6.2.5.20 Remote signal duration
Set remote signal duration.
Info
The availability depends on remote regeneration option programmed in the previous
step.
The contact will close after having received signal for the minimum preset duration.
When the contact closes, remote regeneration signal is acquired and a regeneration will
start (immediate or delayed) as programmed in Remote regeneration [
1. Set the signal duration with
ð Can be adjusted from 1 to 9999 seconds;
2. Press
to validate the selection and advance to the next
parameter.
6.2.5.21 Day of the week
Select the day of the week of regeneration.
Info
Available only for day of the week regeneration type.
Options:
• Sunday (default);
• Monday;