Mitsubishi Heavy Industries V Multi FDC71VNX Technical Manual page 261

Inverter packaged air conditioner
Hide thumbs Also See for V Multi FDC71VNX:
Table of Contents

Advertisement

Information to identify the model(s) to which the information relates :
Outdoor side heat exchanger of heat pump :
Indoor side heat exchanger of heat pump :
Indication if the heater is equipped with a supplementary heater :
if applicable :
electric motor
Parameters shall be declared for the average heating season , parameters for the warmer and colder heating seasons are optional.
Item
Rated heating capacity
Declared heating capacity for part load at indoor temperature 20℃
and outdoor temperature Tj
T
=-7℃
j
T
=+2℃
j
T
=+7℃
j
T
=+12℃
j
T
=bivalent temperature
biv
T
=operation limit
OL
For air-to-water heat pumps :
T
=-15℃
j
(if T
<-20℃)
OL
Bivalent temperature
Degradation
coefficient
heat pumps**
Power consumpiton in modes other than 'active mode'
Off mode
Thermostat-off mode
Crankcase heater mode
Other items
Capacity control
Sound power level,
outdoor measured
Emissions of nitrogen
oxides(if applicable)
GWP of the
refrigerant
Contact details
Mitsubishi heavy industries thermal systems,LTD
** If Cdh is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.
*** from 26 September 2018
Where information relates to multi-spilt air conditioners,the test result and performance data be obtained on the basis of the performance
of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.
FDC125VNX / FDT60VH (x2 units)
air
air
Symbol
Value
Unit
14.0
Prated,h
kW
10.1
Pdh
kW
6.1
Pdh
kW
4.3
Pdh
kW
4.5
Pdh
kW
11.4
Pdh
kW
9.0
Pdh
kW
-
Pdh
kW
-10.0
T
biv
0.25
C
-
dh
P
0.040
kW
OFF
P
0.045
kW
TO
P
0.040
kW
CK
variable
L
70.0
dB
WA
mg/kWh
NOx
-
fuel input
***
GCV
kg CO
2eq
2088
(100years)
260
-
No
Item
Symbol
Seasonal space
heating energy
η s,h
efficiency
Declared coefficient of performance or gas utilization efficiency /
auxiliary energy factor for part load at given outdoor temperatures Tj
T
=-7℃
COPd or
j
GUEh,bin / AEFh,bin
T
=+2℃
COPd or
j
GUEh,bin / AEFh,bin
T
=+7℃
COPd or
j
GUEh,bin / AEFh,bin
T
=+12℃
COPd or
j
GUEh,bin / AEFh,bin
T
=bivalent
COPd or
biv
temperature
GUEh,bin / AEFh,bin
T
=operation limit
COPd or
OL
GUEh,bin / AEFh,bin
For air-to-water heat
COPd or
pumps:T
=-15℃
GUEh,bin / AEFh,bin
j
(if T
<-20℃)
OL
For water-to-air heat
pumps:Operation limit
T
temperature
ol
Supplementary heater
back-up heating capacity
Type of energy input
Standby mode
For air-to-air heat pumps:
air flow-rate,outdoor measured
For water-/brine-to-air heat pumps :
Rated brine or water fiow-rate,
outdoor side heat exchanger
-
'19 • PAC-T-327
Value
Unit
175.4
%
291.0
%
421.0
%
616.0
%
750.0
%
299.0
%
247.0
%
-
%
-
elbu
-
kW
P
0.040
kW
SB
6000
m3/h
-
m3/h
PJF000Z551
A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents