Mitsubishi Heavy Industries V Multi FDC71VNX Technical Manual page 180

Inverter packaged air conditioner
Hide thumbs Also See for V Multi FDC71VNX:
Table of Contents

Advertisement

E58
Compressor startup (Models SRC40-60 only)
E59
Compressor startup failure (Models SRC40-60 only)
E59
Compressor startup failure (Models FDC71-140VNX, 100-140VSX only)
E59
Compressor startup failure (Models FDC100-140VNA / VSA only)
E60
Compressor rotor lock error (Models SRC40-60 only)
Models FDC200, 250VSA
Remote control display
None
Operates but does not cool
None
Operates but does not heat
None
Earth leakage breaker activated
None
Excessive noise/vibration (1/3)
None
Excessive noise/vibration (2/3)
None
Excessive noise/vibration (3/3)
None
Louver motor failure
None
Power source system error (Power source to indoor unit control PCB)
None
Power source system error (Power source to remote control)
INSPECT I/U
INSPECT I/U (When 1 or 2 remote controls are connected)
INSPECT I/U
INSPECT I/U (Connection of 3 units or more remote controls)
Communication error at initial operation
WAIT
None
No display
E1
Remote control communication circuit error
E5
Communication error during operation
E6
Indoor heat exchanger temperature sensor anomaly
E7
Return air temperature sensor anomaly
E8
Heating overload operation
E9
Drain trouble
E10
Excessive number of connected indoor units (more than 17 units) by controlling with one remote control
E11
Address setting error of indoor units
E14
Communication error between master and slave indoor units
E16
Indoor fan motor anomaly
E18
Address setting error of master and slave indoor units
E19
Indoor unit operation check, drain pump motor check setting error
E20
Indoor fan motor rotation speed anomaly
E21
Defective panel switch operation
E28
Remote control temperature sensor anomaly
E35
Cooling overload operation
E36
Discharge pipe temperature error
E37
Outdoor heat exchanger temperature sensor anomaly
E38
Outdoor air temperature sensor anomaly
E39
Discharge pipe temperature sensor anomaly
E40
High pressure error (63H1 activated)
E41
Power transistor overheat
E42
Current cut
E45
Communication error between inverter PCB and outdoor unit control PCB
E48
Outdoor fan motor anomaly
E49
Low pressure error or low pressure sensor anomaly
E51
Inverter or power transistor anomaly
E53
Suction pipe temperature sensor anomaly
E54
Low pressure sensor anomaly
E55
Compressor under dome temperature sensor anomaly (Model FDC250VSA only)
E57
Insufficient refrigerant amount or detection of service valve closure
E59
Compressor startup failure
Description of trouble
179
-
-
'19 • PAC-T-327
244
245
246 · 247
248 · 249
252
Reference page
180
181
182
183
184
185
186
187
188
189
190
197 · 198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
216
217
218
219
220
222
224
225 · 226
227
232
234 · 235
238
239
240
241
243
250 · 251

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents