1.11.2 Troubleshooting flow
(1) List of troubles
Models SRC40, 50, 60ZSX-S, FDC71, 100, 125, 140VNX, 100, 125, 140VSX
FDC100, 125, 140VNA, 100, 125, 140VSA
Remote control display
None
Operates but does not cool
None
Operates but does not heat
None
Earth leakage breaker activated
None
Excessive noise/vibration (1/3)
None
Excessive noise/vibration (2/3)
None
Excessive noise/vibration (3/3)
None
Louver motor failure
None
Power source system error (Power source to indoor unit control PCB)
None
Power source system error (Power source to remote control)
INSPECT I/U
INSPECT I/U (When 1 or 2 remote controls are connected)
INSPECT I/U
INSPECT I/U (Connection of 3 units or more remote controls)
Communication error at initial operation (Models SRC40-60 only)
WAIT
Communication error at initial operation (Models FDC71-140 only)
WAIT
None
No display
E1
Remote control communication circuit error
E5
Communication error during operation
E6
Indoor heat exchanger temperature sensor anomaly
E7
Return air temperature sensor anomaly
E8
Heating overload operation
E9
Drain trouble
E10
Excessive number of connected indoor units (more than 17 units) by controlling with one remote control
E11
Address setting error of indoor units
E14
Communication error between master and slave indoor units
E16
Indoor fan motor anomaly
E18
Address setting error of master and slave indoor units
E19
Indoor unit operation check, drain pump motor check setting error
E20
Indoor fan motor rotation speed anomaly
E21
Defective panel switch operation
E28
Remote control temperature sensor anomaly
E35
Cooling overload operation (Models SRC40-60 only)
E35
Cooling overload operation (Models FDC71-140 only)
E36
Discharge pipe temperature error
E37
Outdoor heat exchanger temperature sensor anomaly
E38
Outdoor air temperature sensor anomaly
E39
Discharge pipe temperature sensor anomaly
E40
Service valve (gas side) closing operation (Models SRC40-60 only)
E40
High pressure error (63H1 activated) (Models FDC71-140 only)
E41
Power transistor overheat (Models FDC71-140VNX, 100-140VSX only)
E42
Current cut
E45
Communication error between inverter PCB and outdoor unit control PCB (Models FDC71-140VNX, 100-140VSX only)
E47
Active filter voltage error (Models SRC40-60 only)
E47
Inverter PCB A/F module anomaly (Model FDC71VNX only)
E47
Active filter anomaly (Models FDC100-140VNA only)
E48
Outdoor fan motor anomaly (Models SRC40-60 only)
E48
Outdoor fan motor anomaly (Models FDC71-140VNX, 100-140VSX only)
E48
Outdoor fan motor anomaly (Models FDC100-140VNA / VSA only)
E49
Low pressure error or low pressure sensor anomaly (Models FDC71-140VNX, 100-140VSX only)
E51
Power transistor anomaly (Models SRC40-60 only)
E51
Inverter and fan motor anomaly (Models FDC71-140 only)
E53
Suction pipe temperature sensor anomaly (Models FDC71-140 only)
E54
Low pressure sensor anomaly (Models FDC71-140VNX, 100-140VSX only)
E57
Insufficient refrigerant amount or detection of service valve closure (Models SRC40-60 only)
E57
Insufficient refrigerant amount or detection of service valve closure (Models FDC71-140 only)
Description of trouble
178
-
-
'19 • PAC-T-327
Reference page
180
181
182
183
184
185
186
187
188
189
190
191-193
194-196
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
225 · 226
227
228
229
230
231
232
233
234 ·235
236
237
239
240
242
243