Nortel Meridian Meridian 1 Implementation Manual page 52

Meridian integrated conference bridge
Hide thumbs Also See for Meridian Meridian 1:
Table of Contents

Advertisement

Page 52 of 208
Configuration procedure
Single-card installation enables up to 10 conferences on one 32-port
MICB card. Each MICB card can use one MICB ACD Group to handle
all the access DNs required
To configure an MICB single-card conference with direct meeting
access, from a maintenance administration position (MAP) terminal
follow the steps in Procedure 2.
Procedure 2
Configure a single-card conference
1
2
3
4
5
553-3001-358
Standard 1.00
Define LENs as FLXA (MSL09 or above) in table LNINV for a 32-port
conference. Refer to
Figure 12 on page
Define the MICB ACDGRP and ACD agents assigned to the MICB card. See
Figure 13 on page
53,
Define the MICB conference and chairperson bridge DNs. Refer to
on page
54. This step provides the following:
a
Main DN for conference ACD groups to access the MICB agents on the
card.
b
Conference DNs and Chairperson DNs.
c
TUI DN and Assistant DN.
d
Single number access conference and chairperson DN.
Define the night service route from ACDGRP NSROUTE.
The night service DN assigned in table OFRT allows conference and
chairperson ACDGRPs to route to the MICB card ACD agents. Table
DNROUTE defines the routes.
table OFRT routing to 214 997 1400 (MICB DN) assigned in table DNROUTE.
Use the following tables and command interfaces (CIs) to datafill the MICB for
single-card configuration:
Table LNINV.
Table ACDGRP.
Table ACDSGRP.
Table ACDLOGIN.
Table CUSTACD (optional).
Table ACDENLOG (optional).
Table DNROUTE.
Table OFRT.
Table OFCENG.
Service Orders.
October 2003
53.
Figure 14 on page
53, and
Figure 17 on page 54
Figure 15 on page
53.