3-2.

Indicators Are Lit Normally

3-2-1.

No Video or OSD Is Displayed on the Panel

Factor
Failure of the panel power line (VGMA,
VDD_DRV) on the BC board
R8703
R8708
47k
47k
1/16W
1/16W
1%
1%
5
RN-CP
RN-CP
L8700
100uH
D8702
RB050LA-40TR
C8719
C8707
0.1
25V
X7R
1608
R8704
R8709
2.2k
39k
1/16W
1/16W
1%
1%
RN-CP
RN-CP
3-2-2.

SDI Signal or Composite Signal Is Not Displayed

SDI 1 Signal Is Not Displayed
Factor
This is considered the failure of IC2200
or IC2401 on the BA board.
BVM-E171
Remedy
Check whether the fuses (F8702, F8703) are blown.
If any of these fuses is blown, replace IC8700.
C8710
D8700
C8721
C8720
0.1
0.01
100
100
25V
UDZSUSTE-1716B
25V
25V
25V
X7R
X7R
1608
1005
Remedy
1.
Input the SDI signal to SDI 1 INPUT.
2.
Measure the C2428 waveform.
Connect and disconnect the SDI signal and check whether there is a change in
the C2428 waveform.
3.
When there is no change and the R2413 voltage is 3.3 V while the SDI
signal is input:
Replace IC2401
When the R2413 is at the ground level or unstable level while the SDI
signal is input:
Replace IC2200
VGMA
15.5V
VDD_GMA
!
JL8700
CL8702
F8702
0.2A
36V
C8717
4.7
25V
X7R
3216
JL8701
F8702
CL8703
VDD_DRV
15.5V 1100mA
VDD_DRV
!
JL8702
F8703
CL8704
3.15A
24V
D8704
PTZ-TE25-18B
F8703
JL8703
GND
CL8705
3-2