Article number
Switching capacity of the outputs
•
•
Load resistance range
•
•
Output voltage
•
Output current
•
•
•
•
Switching frequency
•
•
•
•
Total current of the outputs
•
Cable length
•
Interrupts/diagnostics/status information
Alarms
•
Diagnoses
•
•
Diagnostics indication LED
•
•
•
Technology module TM PTO 2x24V (6ES7138‑6EB00‑0BA0)
Equipment Manual, 09/2021, A5E50983437-AA
with resistive load, max.
on lamp load, max.
lower limit
upper limit
for signal "1", min.
for signal "1" rated value
for signal "1" permissible range, max.
for signal "1" minimum load current
for signal "0" residual current, max.
with resistive load, max.
with inductive load, max.
on lamp load, max.
For signal interface 24 V asymmetrical
Current per module, max.
shielded, max.
Diagnostic alarm
Monitoring the supply voltage
Short-circuit
Monitoring of the supply voltage (PWR-LED)
Channel status display
for module diagnostics
Technical specifications
6ES7138-6EB00-0BA0
0.1 A; 0.5 A for CHn.ED
1 W; 5 W for CHn.ED
240 Ω; 48 ohms for CHn.ED
12 kΩ
23.2 V; L+ (-1.3 V), L+ (-0.8 V) for CHn.ED
0.1 A; 0.5 A for CHn.ED
0.12 A; 0.6 A for CHn.ED
2 mA
0.5 mA
10 kHz
0.5 Hz; According to IEC 60947-5-1, DC-13
10 Hz
200 kHz; For 24 V PTO outputs
1.4 A
600 m; Up to 10 kHz, 50 m at 200 kHz
Yes
Yes
Yes
Yes; green PWR LED
Yes; green LED
Yes; green/red DIAG LED
49