Siemens SIMATIC ET 200SP Product Information

Siemens SIMATIC ET 200SP Product Information

Hide thumbs Also See for SIMATIC ET 200SP:

Advertisement

SIMATIC
ET 200SP
Product information on the
documentation of the ET 200SP
distributed I/O system
Product Information
02/2021
A5E03799595-BG
Preface
Module overview of
ET 200SP
Supplements to ET 200SP
documentation
Using ET 200SP higher than
2 000 m above sea level.
1
2
3

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC ET 200SP

  • Page 1 Preface Module overview of ET 200SP Supplements to ET 200SP SIMATIC documentation Using ET 200SP higher than 2 000 m above sea level. ET 200SP Product information on the documentation of the ET 200SP distributed I/O system Product Information 02/2021 A5E03799595-BG...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers' exposure to cyber threats.
  • Page 4: Table Of Contents

    Table of contents Preface ..............................3 Module overview of ET 200SP ....................... 5 Possible combinations of BaseUnits and I/O modules ............5 CPUs ..........................15 Interface modules ......................17 BaseUnits .......................... 19 I/O modules ........................21 Motor starters ........................23 Accessories ........................
  • Page 5: Module Overview Of Et 200Sp

    This product information includes amendments and corrections to the documentation of the ET 200SP Distributed I/O System (https://support.industry.siemens.com/cs/ww/en/view/109742709). Which I/O modules / motor starters fit on a BaseUnit? The following table provides an overview of the I/O modules / motor starters that fit on the...
  • Page 6 Module overview of ET 200SP 1.1 Possible combinations of BaseUnits and I/O modules I/O module BaseUnit BU15- BaseUnit BU20- Color-coded label for process termi- BU type BU type nals type type B1 type type type type type P16+A1 P16+A0 P12+A0 0+2D +12D/T P12+A4...
  • Page 7 Module overview of ET 200SP 1.1 Possible combinations of BaseUnits and I/O modules I/O module BaseUnit BU15- BaseUnit BU20- Color-coded label for process termi- BU type BU type nals type type B1 type type type type type P16+A1 P16+A0 P12+A0 0+2D +12D/T P12+A4...
  • Page 8 Module overview of ET 200SP 1.1 Possible combinations of BaseUnits and I/O modules I/O module BaseUnit BU15- BaseUnit BU20- Color-coded label for process termi- BU type BU type nals type type B1 type type type type type P16+A1 P16+A0 P12+A0 0+2D +12D/T P12+A4...
  • Page 9 Module overview of ET 200SP 1.1 Possible combinations of BaseUnits and I/O modules I/O module BaseUnit BU15- BaseUnit BU20- Color-coded label for process termi- BU type BU type nals type type B1 type type type type type P16+A1 P16+A0 P12+A0 0+2D +12D/T P12+A4...
  • Page 10 Module overview of ET 200SP 1.1 Possible combinations of BaseUnits and I/O modules I/O module BaseUnit BU15- BaseUnit BU20- Color-coded label for process termi- BU type BU type nals type type B1 type type type type type P16+A1 P16+A0 P12+A0 0+2D +12D/T P12+A4...
  • Page 11 Module overview of ET 200SP 1.1 Possible combinations of BaseUnits and I/O modules I/O module BaseUnit BU15- BaseUnit BU20- Color-coded label for process termi- BU type BU type nals type type B1 type type type type type P16+A1 P16+A0 P12+A0 0+2D +12D/T P12+A4...
  • Page 12 Module overview of ET 200SP 1.1 Possible combinations of BaseUnits and I/O modules I/O module BaseUnit BU15- BaseUnit BU20- Color-coded label for process termi- BU type BU type nals type type B1 type type type type type P16+A1 P16+A0 P12+A0 0+2D +12D/T P12+A4...
  • Page 13 Module overview of ET 200SP 1.1 Possible combinations of BaseUnits and I/O modules Table 1- 2 Possible combinations of BaseUnits and motor starters Selecting the BaseUnit BU-30- BU-30- BU-30- BU-30- BU-30- BU-30- BU-30- BU-30- BU-30- BU-30- MS10 24 V infeed 500 V infeed F-DI terminals (no routing of the F-DI...
  • Page 14 Module overview of ET 200SP 1.1 Possible combinations of BaseUnits and I/O modules F-RS 2.8 - 3RK1308- 9 A HF 0DD00-0CP0 F-RS 4.0 - 3RK1308- 12 A HF 0DE00-0CP0 * The F-DI terminals or F-DI infeed/routing have no function with this combination. Table 1- 3 Combination possibilities between potential distributor BaseUnit and potential distributor terminal block Potential distributor...
  • Page 15: Cpus

    Module overview of ET 200SP 1.2 CPUs CPUs CPUs Number in pack Article number CPU 1510SP-1 PN with server module Pack of 1 6ES7510-1DJ0x-0AB0 CPU 1510SP F-1 PN with server module Pack of 1 6ES7510-1SJ0x-0AB0 CPU 1512SP-1 PN with server module Pack of 1 6ES7512-1DK0x-0AB0 CPU 1512SP F-1 PN with server module...
  • Page 16 Module overview of ET 200SP 1.2 CPUs Note The CM AS-i Master ST and F-CM AS-i Safety ST communication modules are supported as of firmware V1.8 of the CPUs. Note the following additional requirements: CM AS-i Master ST: • Firmware version of the CM AS-i Master ST: V1.1 •...
  • Page 17: Interface Modules

    Module overview of ET 200SP 1.3 Interface modules Interface modules Interface modules Interface modules Number in Article number pack Interface module IM 155-6 PN BA Pack of 1 6ES7155-6AR00-0AN0 Interface module IM 155-6 PN ST Pack of 1 6ES7155-6AA01-0BN0 • with BusAdapter BA 2xRJ45 and server module Pack of 1 6ES7155-6AU01-0BN0...
  • Page 18 Module overview of ET 200SP 1.3 Interface modules Important differences between the interface modules Features IM 155-6 IM 155-6 PN ST IM 155-6 PN/2 HF IM 155-6 MF HF IM 155-6 PN HS IM 155-6 DP HF PN BA IM 155-6 PN/3 HF Bus connec- PROFINET: PROFINET:...
  • Page 19: Baseunits

    Module overview of ET 200SP 1.4 BaseUnits BaseUnits BaseUnits Table 1- 5 BaseUnits for I/O modules BaseUnits (short Color-coded labels* Packaging unit Article number type name) BU15-P16+A10+2D P16: CC00 to CC05 Pack of 1 6ES7193-6BP20-0DA0 A10: CC71 to CC73 Pack of 10 6ES7193-6BP20-2DA0 P16: CC00 to CC05 BU15-P16+A0+2D...
  • Page 20 Module overview of ET 200SP 1.4 BaseUnits Table 1- 6 BaseUnit PotDis PotDis Potential distributor Color-coded labels Packaging unit Article number type (short name) PotDis-BU-P1/D-R CC62 Pack of 1 6ES7193-6UP00-0DP1 PotDis-BU-P1/B-R CC62 Pack of 1 6ES7193-6UP00-0BP1 PotDis-BU-P2/D-B CC63 Pack of 1 6ES7193-6UP00-0DP2 PotDis-BU-P2/B-B CC63...
  • Page 21: I/O Modules

    Module overview of ET 200SP 1.5 I/O modules I/O modules I/O modules Digital I/O modules Packaging unit Article number DI 16x24VDC ST Pack of 1 6ES7131-6BH01-0BA0 Pack of 10 6ES7131-6BH01-2BA0 DI 8x24VDC ST Pack of 1 6ES7131-6BF01-0BA0 Pack of 10 6ES7131-6BF01-2BA0 DI 8x24VDC HF Pack of 1...
  • Page 22 Module overview of ET 200SP 1.5 I/O modules Analog I/O modules Packaging unit Article number AI 8xU BA Pack of 1 6ES7134-6FF00-0AA1 AI 2xU ST Pack of 1 6ES7134-6FB00-0BA1 AI 4xU/I 2-wire ST Pack of 1 6ES7134-6HD01-0BA1 Pack of 10 6ES7134-6HD01-2BA1 AI 2xU/I 2-/4-wire HF Pack of 1...
  • Page 23: Motor Starters

    Module overview of ET 200SP 1.6 Motor starters Technology module Packaging unit Article number TM Count 1x24V Pack of 1 6ES7138-6AA01-0BA0 10 units 6ES7138-6AA01-2BA0 TM PosInput 1 Pack of 1 6ES7138-6BA01-0BA0 10 units 6ES7138-6BA01-2BA0 TM Timer DIDQ 10x24V Pack of 1 6ES7138-6CG00-0BA0 TM Pulse 2x24V Pack of 1...
  • Page 24: Accessories

    Module overview of ET 200SP 1.7 Accessories Fail-safe reversing starter Packaging unit Article number F-RS 0.1 - 0.4 A HF Pack of 1 3RK1308-0DA00-0CP0 F-RS 0.3 - 1 A HF Pack of 1 3RK1308-0DB00-0CP0 F-RS 0.9 - 3 A HF Pack of 1 3RK1308-0DC00-0CP0 F-RS 2.8 - 9 A HF...
  • Page 25 Module overview of ET 200SP 1.7 Accessories General accessories Packaging unit Article number Labeling strips (for labeling the I/O modules) Pack of 1 6ES7193-6LR10-0AA0 • Roll, light gray (with a total of 500 labeling strips) Pack of 1 6ES7193-6LR10-0AG0 • Roll, yellow (with a total of 500 labeling strips) Pack of 10 6ES7193-6LA10-0AA0...
  • Page 26 Module overview of ET 200SP 1.7 Accessories Accessories, color identification labels Packaging unit Article number (push-in terminals), 15 mm wide 16 process terminals (you can find additional information in the I/O Module manual) Pack of 10 6ES7193-6CP00-2MA0 • Gray (terminals 1 to 16); color code CC00 Pack of 10 6ES7193-6CP01-2MA0 •...
  • Page 27 Module overview of ET 200SP 1.7 Accessories Accessories, color identification labels Packaging unit Article number (push-in terminals), 20 mm wide 12 process terminals (you can find additional information in the I/O Module manual) Pack of 10 6ES7193-6CP41-2MB0 • Gray (terminals 1 to 4), red (terminals 5 to 8), blue (terminals 9 to 12);...
  • Page 28 Module overview of ET 200SP 1.7 Accessories Accessories, color identification labels Packaging unit Article number (push-in terminals) PotDis PotDis-BU, 16 potential terminals Pack of 10 6ES7193-6CP62-2MA0 • Red for PotDis-BU-P1/x-R (terminals 1 to 16); color code CC62 Pack of 10 6ES7193-6CP63-2MA0 •...
  • Page 29 Module overview of ET 200SP 1.7 Accessories Accessories, color identification labels Packaging unit Article number (push-in terminals) PotDis PotDis-TB-BR-W, 18 potential terminals Pack of 10 6ES7193-6CP11-2MT0 • Yellow/green (terminals 1 to 18); color code CC11 Pack of 10 6ES7193-6CP12-2MT0 • Red (terminals 1 to 18);...
  • Page 30 Module overview of ET 200SP 1.7 Accessories Technical specifications BU Cover Article number 6ES7133-6CV20-1AM0 General information Product type designation BU cover Ambient conditions Ambient temperature during operation -40 °C • horizontal installation, min. 60 °C • horizontal installation, max. -40 °C •...
  • Page 31: Supplements To Et 200Sp Documentation

    Supplements to ET 200SP documentation System Manual ET 200SP System Manual, edition 09/2019 Section 4.5.1 Basics NOTICE AUX bus as PE bar If you use an AUX bus as a protective conductor bar, attach the yellow-green color identification labels to the AUX terminals, and establish a functional connection to the central protective conductor connection.
  • Page 32 Supplements to ET 200SP documentation 2.1 System Manual Section 14.1 Standards, approvals and safety instructions ATEX approval According to EN 60079-15 (Electrical apparatus for potentially explosive atmospheres - Part 15: Type of Protection "n") and EN 60079-0 (Electrical apparatus for potentially explosive gas atmospheres - Part 0: General requirements).
  • Page 33 Supplements to ET 200SP documentation 2.1 System Manual According to IEC 60079-7 (Explosive atmospheres - Part 7: Equipment protection by increase safety “e”) and IEC 60079-0 (Explosive atmospheres - Part 0: Equipment - General requirements). Special conditions in hazardous area: 1.
  • Page 34 Supplements to ET 200SP documentation 2.1 System Manual Section 7.4 Value status Value status (QI, quality information) refers to status information of I/O channels that is made available to the user program via the process image input (PII). However, since the value status is partly derived from the diagnostics, there may be a time delay between the occurrence of the error and the message depending on the diagnostics.
  • Page 35 Supplements to ET 200SP documentation 2.1 System Manual Activating value status Value status depending on the respective configuration variant STEP 7 TIA (integrated I/O STEP 7 HSP (PROFINET GSD PROFINET (can GSD PROFIBUS module; PROFINET and and PROFIBUS) be integrated in (can be integrated PROFIBUS) STEP 7 TIA and STEP...
  • Page 36: Baseunits Manual

    6ES7193-6KD00-3AA0 • Coding element (type D) How to proceed when changing the coding element is described in the section "Changing the type of an I/O module" in the system manual SIMATIC ET 200SP Distributed I/O System (https://support.industry.siemens.com/cs/ww/en/view/58649293). BaseUnits manual 2.2.1 Special consideration for BaseUnits with functional versions <...
  • Page 37: Cpu Manuals

    The Technical Specifications section in the CPU equipment manuals indicates the status of the technical specification at the respective edition date. You can find a data sheet including daily updated technical specifications on the Internet (https://support.industry.siemens.com/cs/ww/en/ps/13888/td). Manual CPU 1512SP-1 PN, Edition 09/2016 Section 4.1 Status and error display of the CPU...
  • Page 38: Interface Module Manuals

    Supplements to ET 200SP documentation 2.4 Interface module manuals Interface module manuals Configuration notes on interface modules depending on the I/O modules Module IM 155-6 PN ST IM 155-6 PN HF IM 155-DP HF 155- IM 155-6 PN/2 HF V4.2 and 6 PN higher IM 155-6 PN/3 HF V4.2 and...
  • Page 39 Supplements to ET 200SP documentation 2.4 Interface module manuals Module IM 155-6 PN ST IM 155-6 PN HF IM 155-DP HF 155- IM 155-6 PN/2 HF V4.2 and 6 PN higher IM 155-6 PN/3 HF V4.2 and higher Firm- V3.2 ware ver- sion...
  • Page 40 Supplements to ET 200SP documentation 2.4 Interface module manuals Equipment Manual IM 155-6 PN BA, Edition 03/2015 Status of the supply voltage Load voltage diagnostics are only valid if the station started up with a valid and complete configuration. • For modules in the following table without a parameter assignment, the status of the supply voltage is always signaled as "1"...
  • Page 41 Supplements to ET 200SP documentation 2.4 Interface module manuals Table 2- 2 Example calculation Configured update time Backplane bus cycle time (integer multiple, minimum 1 ms) 250 µs 4 x 250 μs = 1000 μs 750 μs 2 x 750 μs = 1500 μs 1000 μs 1000 μs 2000 μs...
  • Page 42 Supplements to ET 200SP documentation 2.4 Interface module manuals Equipment Manual IM 155-6 PN ST, Edition 04/2017 You can perform a firmware update to V4.1 for IM 155-6 PN ST interface modules with the article number 6ES7155-6AU00-0BN0. If you perform hardware detection of the IO device in the TIA Portal as of V15.0 after the firmware update to V4.1, the device name is displayed as not assigned in the "PROFINET device name"...
  • Page 43 Supplements to ET 200SP documentation 2.4 Interface module manuals Requirements The supply voltage to the interface module must be switched on. Required tool 3 to 3.5 mm screwdriver (for resetting via the RESET button) Procedure 1. Remove the interface module from the mounting rail and swivel it downwards. 2.
  • Page 44 Supplements to ET 200SP documentation 2.4 Interface module manuals Equipment Manual IM 155-6 DP HF, Edition 10/2018 Section 2.2.1 Requirements Table 2- 3 Version dependencies of other module functions Function Product Firmware Configuration software version of version of Configura- STEP 7 as of STEP 7 (TIA the module the module...
  • Page 45: I/O Module Manuals

    Supplements to ET 200SP documentation 2.5 I/O module manuals I/O module manuals Configuration notes on the I/O modules (supplement to Product overview section in the manual) I/O module Article number Firmware STEP 7 (TIA STEP 7 V5.5 SP3 version Portal) Digital input modules DI 16x24VDC ST 6ES7131-6BH00-...
  • Page 46 Supplements to ET 200SP documentation 2.5 I/O module manuals I/O module Article number Firmware STEP 7 (TIA STEP 7 V5.5 SP3 version Portal) Analog input modules AI 8xU BA 6ES7134-6FF00- V1.0.0 HSP0126 HSP0227 V5.0 0AA1 AI 2xU ST 6ES7134-6FB00- V1.0.0 HSP0160 HSP0227 V6.0 0BA1...
  • Page 47: Digital Module Device Manuals

    Supplements to ET 200SP documentation 2.5 I/O module manuals 2.5.1 Digital module device manuals Manuals for I/O modules ST, BA When you have disabled all channels of the I/O module, a diagnostic message is still generated in the case of a fault if the "No supply voltage L+" diagnostics is enabled. For the following I/O modules, this behavior is corrected as of firmware version >...
  • Page 48 Supplements to ET 200SP documentation 2.5 I/O module manuals Manual DI 8xNAMUR HF, Edition 02/2014 Section A.2 Parameter assignment and structure of parameter data record With data records 0 to 7, you can configure individual channels. When the interface module IM 155-6 DP HF (PROFIBUS DP) is used and data records 0 and 1 are read, the module returns the diagnostics data records and not the parameter data records of the DI 8xNAMUR HF.
  • Page 49 Supplements to ET 200SP documentation 2.5 I/O module manuals Manual Digital Output Module DQ 4x24..230VAC/2A ST, Edition 03/2015 Section 3.1 Wiring and block diagram The following figure shows the block diagram and an example of the pin assignment of the digital output module DQ 4x24..230VAC/2A ST on the BaseUnit BU type B1.
  • Page 50 Supplements to ET 200SP documentation 2.5 I/O module manuals Section 3.1 Pin assignment; Supply voltage fuse protection The module has neither short-circuit protection nor overload protection. Protect the module from being destroyed by impermissible high current and install a fine fuse in the supply line. The maximum rated current of the fine fuse depends on the hardware function status (FS) of the module.
  • Page 51 Supplements to ET 200SP documentation 2.5 I/O module manuals Manual DQ 4x24..230VAC/2A HF, Edition 02/2018 Section 3.1.1. und 4.1.1 Wiring and block diagram The following figure shows an example for the pin assignment of the digital output module DQ 4x24..230VAC/2A HF on the BaseUnit BU type U0 (3-wire connection) in combination with a potential distribution module and terminal block.
  • Page 52 Supplements to ET 200SP documentation 2.5 I/O module manuals Digital output module DQ 8x24VDC/0.5A ST, edition 02/2019 Connection: 3-wire connection of actuators The following figure shows an example of the pin assignment of the digital output module DQ 8×24VDC/0.5A ST on the BaseUnit BU type A0 with AUX terminals (3-wire connection). ①...
  • Page 53: Analog Module Device Manuals

    Supplements to ET 200SP documentation 2.5 I/O module manuals Manual RQ 4x120VDC-230VAC/5A NO MA ST, Edition 12/2015 Section 3.1 Wiring and block diagram The AUX terminals of the self-assembling voltage bus can be used for the connection of the protective conductor (PE) or for voltages up to a maximum of 24 V DC. 2.5.2 Analog module device manuals Manuals for analog input modules...
  • Page 54 Supplements to ET 200SP documentation 2.5 I/O module manuals New section in Appendix B: "Measured values for wire break" Table 2- 4 Measured values at a wire break depending on enabled diagnostics Programmable diagnos- Measured value Explanation tics Wire break Underflow Enable Enable...
  • Page 55 Supplements to ET 200SP documentation 2.5 I/O module manuals Manual AI Energy Meter 480VAC ST, Edition 12/2015 For configuration with STEP 7 V13 or higher (TIA Portal), real values between -7x10 +7x10 can be input. This is true for configuration via HSP and via GSD file (PROFINET). For configuration with STEP 7 V5.5 SP4 as of HF7, configuration by means of GSD file (PROFINET) with REAL values of -1.175x10 to +3.402x10...
  • Page 56 Supplements to ET 200SP documentation 2.5 I/O module manuals If you use the user-data mapping via data record DS 130, note that the texts for the measured variables are also displayed incorrectly during configuration. During configuration of the measured variables for the total active, reactive, and apparent power, select the following texts: Desired measured variable for the user-data Text to select during configuration...
  • Page 57 Supplements to ET 200SP documentation 2.5 I/O module manuals Manuals for analog output modules Manual Edition Analog output module AQ 2xI ST 12/2015 Analog output module AQ 2xU/I HF 02/2014 Analog output module AQ 2xU/I HS 09/2016 Analog output module AQ 4xU/I ST 03/2016 "Representation of analog values in the current output ranges"...
  • Page 58 Supplements to ET 200SP documentation 2.5 I/O module manuals Manuals for analog input modules Manual Edition AI 8xI 2/4-wire Basic (6ES7134-6GF00-0AA1) 03/2015 AI 4xU/I 2-wire ST (6ES7134-6HD01-0BA1) 09/2019 AI 2xI 2/4-wire ST (6ES7134-6GB00-0BA1) 04/2018 AI 2xU/I 2-, 4-wire HS (6ES7134-6HB00-0DA1) 09/2018 AI 4xI 2/4-wire ST (6ES7134-6GD01-0BA1) 09/2018...
  • Page 59 Supplements to ET 200SP documentation 2.5 I/O module manuals Table 2- 9 Measured values in case of a line break in a TC measurement with enabled reference junction (reference chan- nel) depending on enabled diagnostic information Case Programmable diagnostics Measured value Reference channel TC channel Reference channel...
  • Page 60 Supplements to ET 200SP documentation 2.5 I/O module manuals Manual AI 4xTC HS (6ES7134-6JD00-0DA1) New section in Appendix B: "Measured values for wire break and reference channel mode" Table 2- 10 Measured values for a wire break depending on enabled diagnostics and parameters in TC operating mode Parameters Measured value Explanation...
  • Page 61: Communications Module Manuals

    Supplements to ET 200SP documentation 2.5 I/O module manuals Explanations of the cases: Case Reference channel TC channel The "wire break" diagnostics is reported. This has a high- The "Reference channel error" diagnostics is reported if er priority than the "Underflow" diagnostics.* this is enabled.
  • Page 62 Supplements to ET 200SP documentation 2.5 I/O module manuals Communications module IO-Link Master CM 4xIO-Link, Edition 10/2017 Section Connecting, Wiring and block diagram Connection: 2-wire and 3-wire connection in DQ operating mode: ① 2-wire connection 1 A to 10 A AUX terminals ②...
  • Page 63: Using Et 200Sp Higher Than 2 000 M Above Sea Level

    "Technical specifications" section of the respective modules in the equipment manuals. Constraints on operation of ET 200SP at altitudes > 2 000 m are described in SIMATIC ET 200SP Distributed I/O System (https://support.industry.siemens.com/cs/ww/en/view/58649293). Currently valid markings and approvals Note Information on the components of ET 200SP The currently valid markings and approvals are printed on the ET 200SP modules.
  • Page 64: Listing Of The Modules

    Using ET 200SP higher than 2 000 m above sea level. 3.2 Listing of the modules Shipping and storage conditions for modules ET 200SP meets the requirements of IEC 61131-2 regarding transport and storage conditions. The following information applies to modules that are shipped and/or stored in their original packaging.
  • Page 65 Using ET 200SP higher than 2 000 m above sea level. 3.2 Listing of the modules Type Name Article number Ambient temperature Max. instal- lation alti- Lower Upper As of revi- tude [m] limit [°C] limit [°C] sion Open Controller CPU 1515SP PC2 + HMI 6ES7677-2DB42-0GL0 +60 °C...
  • Page 66 Using ET 200SP higher than 2 000 m above sea level. 3.2 Listing of the modules Interface modules Type Name Article number Ambient temperature Max. in- stallation Lower Upper As of revi- altitude limit [°C] limit [°C] sion IM 155-6 PN BA 6ES7155-6AR00-0AN0 +60 °C FS 04...
  • Page 67 Using ET 200SP higher than 2 000 m above sea level. 3.2 Listing of the modules Digital input modules Type Name Article number Ambient temperature Max. in- stallation Lower Upper As of revi- altitude limit [°C] limit [°C] sion DI 4x120…230VAC ST 6ES7131-6FD01-0BB1 +60 °C FS 02...
  • Page 68 Using ET 200SP higher than 2 000 m above sea level. 3.2 Listing of the modules Digital output modules Type Name Article number Ambient temperature Max. instal- lation alti- Lower Upper As of revi- tude [m] limit [°C] limit [°C] sion DQ 8x24VDC/0.5A BA 6ES7132-6BF01-0AA0...
  • Page 69 Using ET 200SP higher than 2 000 m above sea level. 3.2 Listing of the modules Analog modules Type Name Article number Ambient temperature Max. in- stallation Lower Upper As of altitude limit [°C] limit [°C] revision AI 2xI 2/4-wire ST 6ES7134-6GB00-0BA1 +60 °C FS 04...
  • Page 70 Using ET 200SP higher than 2 000 m above sea level. 3.2 Listing of the modules Technology modules and communication modules Type Name Article number Ambient temperature Max. installa- Lower Upper As of tion alti- limit [°C] limit [°C] revision tude [m] TM Count 1x24V 6ES7138-6AA01-0BA0...
  • Page 71 Using ET 200SP higher than 2 000 m above sea level. 3.2 Listing of the modules Motor starters and BaseUnits BU type P0 Type Name Article number Ambient temperature Max. installa- Lower Upper As of revi- tion alti- limit [°C] limit [°C] sion tude [m]...
  • Page 72 Using ET 200SP higher than 2 000 m above sea level. 3.2 Listing of the modules BaseUnits BU type A0 and A1 Type Name Article number Ambient temperature Max. installa- Lower Upper As of tion alti- limit [°C] limit [°C] revision tude [m] BU type A0...
  • Page 73 Using ET 200SP higher than 2 000 m above sea level. 3.2 Listing of the modules BaseUnits BU type B0 bis U0 Type Name Article number Ambient temperature Max. installation altitude [m] Lower limit Upper limit As of revi- [°C] [°C] sion BU type B0...
  • Page 74 Using ET 200SP higher than 2 000 m above sea level. 3.2 Listing of the modules Potential distributor Type Name Article number Ambient temperature Max. installa- Lower Upper As of revi- tion alti- limit [°C] limit [°C] sion tude [m] PotDis PotDis-BU-P1/D-R 6ES7193-6UP00-0DP1...
  • Page 75: Restrictions

    • Make sure that the power supplies you use are also rated for altitudes > 2 000 m. • The "Safety-related shutdown of standard modules" function, as described in the Internet (https://support.industry.siemens.com/cs/ww/en/view/39198632), is only approved up to a maximum of 2 000 m.