1.9-ltr. / 66 kw (tdi) engine fuel injection and glow plug system
Table of Contents

Advertisement

OCTAVIA
Edition 03.98
S00.5111.52.20
Glow Plug System
Testing glow plug system
Testing operation
Special tools, testers and aids required
♦ Hand-held multimeter (e.g. V.A.G 1526)
♦ Current flow diagram
Test conditions
l Battery voltage at least 11.5 V
l Diesel direct injection system control unit
(J248) o.k.
l Strip fuse for glow plugs (S 132) o.k.
Test procedure
-
Switch off the ignition.
K -
Unplug connector -1- at the coolant tempera-
ture sender (G62) -2-.
Note:
When the connector is unplugged from the
sender, the „cold" engine state is simulated and
appropriate glow plug heating operation is car-
ried out when the ignition is switched on.
-
Unplug the glow plug connectors from the
glow plugs.
-
Connect the multimeter for voltage measure-
ment to a glow plug connector and to engine
earth.
-
Switch on the ignition.
approx. battery voltage
should be displayed for about 20 seconds.
If no voltage is present:
-
Rectify any open circuit in the wiring or short
circuit.
⇒ Current Flow Diagrams, Electrical Fault
Finding and Fitting Locations binder
During the simulated glow plug heating opera-
tion, the glow period warning lamp (K29) should
come on.
28
------------ 28-1 ------------