Page 1
SRX320 Services Gateway Hardware Guide Published 2020-08-19...
Page 2
END USER LICENSE AGREEMENT The Juniper Networks product that is the subject of this technical documentation consists of (or is intended for use with) Juniper Networks software. Use of such software is subject to the terms and conditions of the End User License Agreement (“EULA”) posted at https://support.juniper.net/support/eula/.
Page 4
SRX320 Transceiver Specifications and Pinouts | 37 SRX320 Transceiver Support | 37 RJ-45 Connector Pinouts for the SRX320 Services Gateway Ethernet Port | 37 RJ-45 Connector Pinouts for the SRX320 Services Gateway Console Port | 38 Mini-USB Connector Pinouts for the SRX320 Services Gateway Console Port | 39...
Page 5
Troubleshooting the SRX320 | 73 Troubleshooting Resources for the SRX320 Services Gateway Overview | 73 Troubleshooting Chassis and Interface Alarm Messages on the SRX320 Services Gateway | 73 Troubleshooting the Power System on the SRX320 Services Gateway | 75 Using the RESET CONFIG Button | 75...
Page 6
Locating the SRX320 Services Gateway Mini-Physical Interface Module Serial Number Label | 80 Listing the SRX320 Services Gateway Component Details with the CLI | 80 Required Tools and Parts for Packing the SRX320 Services Gateway | 81 Packing the SRX320 Services Gateway for Shipment | 81...
Page 7
General Electrical Safety Guidelines and Warnings | 109 SRX320 Services Gateway Agency Approvals | 110 SRX320 Services Gateway Acoustic Noise Compliance Statements | 111 SRX320 Services Gateway EMC Requirements | 112 Canada | 112 European Community | 112 Israel | 112...
Use this guide to install hardware and perform initial software configuration, routine maintenance, and troubleshooting for the SRX320 Services Gateway. After completing the installation and basic configuration procedures covered in this guide, refer to the Junos OS documentation for information about further software configuration.
If the example configuration contains the top level of the hierarchy (or multiple hierarchies), the example is a full example. In this case, use the load merge command. If the example configuration does not start at the top level of the hierarchy, the example is a snippet. In this case, use the load merge relative command.
Merging a Snippet To merge a snippet, follow these steps: 1. From the HTML or PDF version of the manual, copy a configuration snippet into a text file, save the file with a name, and copy the file to a directory on your routing platform. For example, copy the following snippet to a file and name the file ex-script-snippet.conf.
Page 11
Table 1: Notice Icons Icon Meaning Description Informational note Indicates important features or instructions. Caution Indicates a situation that might result in loss of data or hardware damage. Warning Alerts you to the risk of personal injury or death. Laser warning Alerts you to the risk of personal injury from a laser.
Page 12
Table 2: Text and Syntax Conventions (continued) Convention Description Examples Italic text like this Represents variables (options for Configure the machine’s domain which you substitute a value) in name: commands or configuration [edit] statements. root@# set system domain-name domain-name Text like this Represents names of configuration To configure a stub area, include statements, commands, files, and...
URL or page number, and software version (if applicable). Requesting Technical Support Technical product support is available through the Juniper Networks Technical Assistance Center (JTAC). If you are a customer with an active Juniper Care or Partner Support Services support contract, or are...
JTAC hours of operation—The JTAC centers have resources available 24 hours a day, 7 days a week, 365 days a year. Self-Help Online Tools and Resources For quick and easy problem resolution, Juniper Networks has designed an online self-service portal called the Customer Support Center (CSC) that provides you with the following features: Find CSC offerings: https://www.juniper.net/customers/support/...
With a desktop form-factor chassis, the SRX320 Services Gateway has six 1 G Ethernet ports, two 1 G SFP ports, 4 GB of DRAM memory, 8 GB of flash memory, and two Mini-Physical Interface Module (Mini-PIM) slots.
Replacing Mini-Physical Interface Modules in the SRX320 Services Gateway | 70 Benefits of the SRX320 Services Gateway High performance—The SRX320 supports up to 1-Gbps firewall and 300-Mbps IPsec VPN, and is suited for small distributed enterprise branch office deployments. Simplified deployment with minimal manual intervention—The Zero Touch Provisioning (ZTP) feature enables you to provision and configure the SRX300 line automatically, thereby reducing operational complexity and simplifying the provisioning of new sites.
SRX320 Services Gateway Interface Modules Overview | 23 SRX320 Services Gateway Chassis Overview The SRX320 Services Gateway chassis measures 1.73 in. high, 11.81 in. wide, and 7.52 in. deep. The PoE model weighs 3.4 lb. and the non-PoE model weighs 3.28 lb.
Page 19
Figure 1: SRX320 Services Gateway Front Panel Table 3 on page 19 provides details about the front panel components. Table 3: SRX320 Services Gateway Front Panel Components Number Component Description Reset Config button Returns the services gateway to the rescue configuration or the factory-default configuration.
Page 20
Table 3: SRX320 Services Gateway Front Panel Components (continued) Number Component Description 1-GbE RJ-45 ports Six LAN ports (0/0 to 0/5) The ports have the following characteristics: Operate in full-duplex and half-duplex modes Support autonegotiation The ports can be used to:...
Blinking green—There is activity on the 1 G link. Off—There is no link activity. SRX320 Services Gateway Back Panel Figure 3 on page 22 shows the back panel of the SRX320 Services Gateway and Table 6 on page 22 lists the components on the back panel.
Page 22
Figure 3: SRX320 Services Gateway Back Panel Table 6: SRX320 Services Gateway Back Panel Components Number Component Description Lock Provides the capability to lock and secure the device at the installation site. Fans Keeps all the services gateway components within the acceptable temperature range.
SRX320 Cooling System The cooling system for the SRX320 Services Gateway includes two fixed fans. The fans draw air through vents on the front of the chassis and exhaust the air through the back of the chassis. The airflow produced by the fans keeps device components within the acceptable temperature range.
Figure 4: Airflow Through the SRX320 Services Gateway Chassis RELATED DOCUMENTATION SRX320 Services Gateway Clearance Requirements for Airflow and Hardware Maintenance | 35 SRX320 Power System IN THIS SECTION Understanding the SRX320 Services Gateway Power Supply | 25 SRX320 Services Gateway Power Specifications and Requirements | 25...
Understanding the SRX320 Services Gateway Power Supply The power supply for the SRX320 Services Gateway is external. You must use the following power supply adapters provided by Juniper Networks to provide power to the services gateway. 75 W, 12 V power supply adapter for non-PoE models...
Table 7: Power Specifications for the SRX320 Services Gateway Power Supply Adapter (continued) Power Supply Adapter Requirement Specification Current 1.3 A maximum for standard model (for non-PoE model) 3.25 A maximum (for PoE model) WARNING: The AC power cord for the services gateway is intended for use with only the power supply adapter provided with the device.
Page 27
Table 8: AC Power Cord Specifications (continued) Country/Region Electrical Specifications Plug Standards Juniper Model Number Europe (except Italy, 250 VAC, 10 A, 50 Hz CEE (7) VII Type VIIG CBL-JX-PWR-EU Switzerland, and United Kingdom) India 250 VAC, 10 A, 50 Hz...
C HAPTER Site Planning, Preparation, and Specifications SRX320 Site Preparation Checklist | 29 SRX320 Site Guidelines and Requirements | 31 SRX320 Transceiver Specifications and Pinouts | 37...
SRX320 Services Gateway Rack-Mounting Requirements and the minimum requirements. Warnings Rack Installation Plan the rack location, “Installing the SRX320 Services Gateway in a Rack” on page 48 including required space clearances. Secure the rack to the floor and building structure.
Page 30
Table 9: Site Preparation Checklist for SRX320 Services Gateway Installation (continued) P e r f o r m e d Item or Task Additional Information D a t e N o t e s Verify that your cabinet SRX320 Services Gateway Cabinet Size and Clearance Requirements meets the minimum requirements.
Cabinet Requirements | 36 SRX320 Services Gateway General Site Guidelines The following precautions help you plan an acceptable operating environment for your SRX320 Services Gateway and avoid environmentally caused equipment failures: For the cooling system to function properly, the airflow around the chassis must be unrestricted. Allow sufficient clearance between the front and back of the chassis and adjacent equipment.
SRX320 Services Gateway Environmental Specifications Table 10 on page 32 provides the required environmental conditions for normal SRX320 Services Gateway operations. Table 10: Environmental Specifications for the SRX320 Services Gateway Description Value Altitude No performance degradation up to 10,000 ft (3048 m)
Page 33
Table 11: Site Electrical Wiring Guidelines for the SRX320 Services Gateway Site Wiring Factor Guideline Signaling Limitations To ensure that signaling functions optimally: Install wires correctly. Improperly installed wires can emit radio interference. Do not exceed the recommended distances or pass wires between buildings.
SRX320 Services Gateway Grounding Specifications To meet safety and electromagnetic interference (EMI) requirements and to ensure proper operation, the SRX320 Services Gateway must be adequately grounded before power is connected. You must provide a grounding lug to connect the services gateway to earth ground.
SRX320 Services Gateway Clearance Requirements for Airflow and Hardware Maintenance When planning the installation site for the SRX320 Services Gateway, you need to allow sufficient clearance around the device. Consider the following: For the operating temperature of the services gateway to be optimal, the airflow around the chassis must be unrestricted.
Maximum permissible ambient temperature when two devices are placed side by side in a 19 in. rack is 40° C. The spacing of the mounting brackets and flange holes on the rack and device mounting brackets are as follows: The holes within each rack set are spaced at 1 U (1.75 in. or 4.5 cm). The mounting brackets and front-mount flanges used to attach the chassis to a rack are designed to fasten to holes spaced at rack distances of 1 U (1.75 in.).
The Hardware Compatibility Tool enables you to search by product, displaying all the transceivers supported on that device, or category, by interface speed or type. The list of supported transceivers for the SRX320 is located at https://apps.juniper.net/hct/product/#prd=SRX320.
Table 14: RJ-45 Connector Pinouts for the SRX320 Services Gateway Ethernet Port Signal BI_DA+ BI_DA BI_DB+ BI_DC+ BI_DC BI_DB BI_DD+ BI_DD RJ-45 Connector Pinouts for the SRX320 Services Gateway Console Port Table 15 on page 38 describes the RJ-45 connector pinouts for the console port.
Mini-USB Connector Pinouts for the SRX320 Services Gateway Console Port The SRX320 Services Gateway has two console ports: an RJ-45 Ethernet port and a mini-USB Type-B port. If your management device (laptop or PC) does not have a DB-9 male connector pin or an RJ-45...
Initial Installation and Configuration SRX320 Installation Overview | 41 Unpacking and Mounting the SRX320 | 43 Connecting the SRX320 to Power | 52 Connecting the SRX320 Services Gateway to a Management Console | 57 Configuring Junos OS on the SRX320 | 58...
SRX320 Services Gateway Autoinstallation Overview | 41 SRX320 Services Gateway Installation Overview After you have prepared the site for installation and unpacked the SRX320 Services Gateway, you are ready to install the device. It is important to proceed through the installation process in the following order: 1.
Page 42
autoinstallation feature enables you to deploy multiple services gateways from a central location in the network. If you are setting up many devices, autoinstallation can help automate the configuration process by loading configuration files onto new or existing devices automatically over the network. You can use either the J-Web interface or the CLI to configure a device for autoinstallation.
Installing the SRX320 Services Gateway in a Rack | 48 Unpacking the SRX320 Services Gateway The SRX320 Services Gateway is shipped in a cardboard carton and secured with foam packing material. The carton also contains an accessory box and quick-start instructions.
Verifying Parts Received with the SRX320 Services Gateway The SRX320 Services Gateway shipment package contains a packing list. Check the parts in the shipment against the items on the packing list. The packing list specifies the part numbers and carries a brief description of each part in your order.
The horizontal position is the standard installation position. To install the device in a horizontal position: 1. Make sure that the rubber feet are attached to the chassis. 2. Place the device on a desk with the Juniper Networks logo, which is embossed on the top cover, facing NOTE:...
Page 46
To install the device on a wall: 1. Place the device on a flat, level surface with the Juniper Networks logo, which is embossed on the top cover, facing up. Ensure that the rubber feet are attached to the bottom of the chassis.
Page 47
Figure 9: Orienting the SRX320 Services Gateway on a Wall 7. Verify that the mounting screws on one side are aligned with the mounting screws on the opposite side and that the device is level. Figure 10: Mounting the SRX320 Services Gateway on a Wall...
Installing the SRX320 Services Gateway in a Rack You can mount an SRX320 Services Gateway in four-post (telco) racks, enclosed cabinets, and open-frame racks. NOTE: The SRX320 Services Gateway cannot be center-mounted in racks. Before mounting the SRX320 Services Gateway in a rack: Verify that the installation site meets the requirements described in “Site Preparation Checklist for the...
Page 49
1. Position a mounting bracket on each side of the chassis as shown in Figure 11 on page 49 Figure 12 on page Figure 11: Positioning the Mounting Brackets (75 W Power Supply Adapter) Figure 12: Positioning the Mounting Brackets (280 W Power Supply Adapter) 2.
Page 50
NOTE: The 280 W power adapter for the PoE model is more than 1 RU tall. When installing the PoE model in a rack, note that you will not be able to install devices in the adjacent slots in a rack. Figure 14: Positioning the Power Supply Adapter 4.
Page 51
Figure 15: Positioning the SRX320 Services Gateway (PoE Model with 280 W Power Supply Adapter) in a Rack Figure 16: Positioning the SRX320 Services Gateway (with 75 W Power Supply Adapter) in a Rack...
Connecting the SRX320 to Power IN THIS SECTION Required Tools and Parts for Grounding the SRX320 Services Gateway | 52 Connecting the SRX320 Services Gateway Grounding Cable | 53 Connecting the SRX320 Services Gateway to the Power Supply | 54...
Electrostatic discharge (ESD) grounding wrist strap Wire cutters Connecting the SRX320 Services Gateway Grounding Cable You ground the services gateway by connecting a grounding cable to earth ground and then attaching it to the chassis grounding point located on the back panel of the device using one M4 grounding screw.
Figure 17: Connecting the SRX320 Services Gateway Grounding Cable NOTE: The device should be permanently connected to ground during operation. SEE ALSO SRX320 Services Gateway Grounding Specifications | 34 Connecting the SRX320 Services Gateway to the Power Supply To connect the device to the power supply:...
Figure 18: Connecting the SRX320 Services Gateway to the Power Supply SEE ALSO Understanding the SRX320 Services Gateway Power Supply | 25 SRX320 Services Gateway Power Specifications and Requirements | 25 Powering On the SRX320 Services Gateway To power on the services gateway: 1.
CLI request system power-off command. Powering Off the SRX320 Services Gateway You can power off the services gateway in one of the following ways: Graceful shutdown—Press and immediately release the Power button. The device begins gracefully shutting down the operating system and then powers itself off.
1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis. 2. Plug the RJ-45 end of the cable into the CONSOLE port on the SRX320 Services Gateway as shown Figure 19 on page...
RELATED DOCUMENTATION Accessing J-Web on the SRX320 Services Gateway | 58 Configuring the SRX320 Services Gateway Using the J-Web Setup Wizard | 58 Configuring Junos OS on the SRX320 IN THIS SECTION SRX320 Services Gateway Software Configuration Overview | 59...
Viewing Factory-Default Settings | 66 SRX320 Services Gateway Software Configuration Overview The services gateway is shipped with the Juniper Networks Junos operating system (Junos OS) preinstalled and ready to be configured when the device is powered on. You can perform the initial software configuration of the services gateway by using the browser-based setup wizard or by using the command-line interface (CLI).
(logical) untrust ISP assigned* *Only if the LTE Mini-PIM is present The SRX320 device is shipped with the following services and protocols enabled by default: Table 23: Services, Protocols, and Startup Mode Services Protocols Device Startup Mode RSTP (all interfaces)
Figure 20: Connecting the SRX320 to a Management Device The SRX320 functions as a DHCP server and automatically assigns an IP address to the laptop. 3. Ensure that the management device acquires an IP address on the 192.168.1.0/24 network from the device.
Silicon Labs page. Figure 21: Connecting to the Console Port on the SRX320 Services Gateway 4. Start your asynchronous terminal emulation application (such as Microsoft Windows HyperTerminal) and select the appropriate COM port to use (for example, COM1).
Page 63
New password: password Retype new password: password 9. Commit the configuration to activate it on the device. [edit] root# commit NOTE: For information on the factory-default settings, see “Understanding SRX320 Services Gateway Factory-Default Settings” on page...
The SRX320 already has factory-default settings configured to make it a plug and play device. So all you have to do to get the SRX320 up and running is connect it to your LAN and WAN networks. 1. Connect the WAN network to port 0/0 to obtain a dynamic IP address.
Customize the Configuration Using J-Web You can modify the configuration using J-Web. Have the following information ready before you start the configuration process: Hostname Root authentication password IP address for the NTP server IP address for the DNS server IP address for the management interface 1.
4. Set the time and configure the DNS server: a. Set the time manually or configure an NTP server. b. Select the time zone from the drop-down box. c. Type the IP address for the DNS server. d. Click Next. 5.
Page 67
user@host>file list /etc/config 3. View the required default configuration file. user@host> file show /etc/config/<config file name> When you commit changes to the configuration, a new configuration file is created, which becomes the active configuration. If the current active configuration fails, you can use the load factory-default command to revert to the factory-default configuration.
Maintaining the SRX320 Components IN THIS SECTION Required Tools and Parts for Maintaining the SRX320 Services Gateway Hardware Components | 69 Routine Maintenance Procedures for the SRX320 Services Gateway | 69 Maintaining the SRX320 Services Gateway Cooling System Components | 70...
SRX320 Power System | 24 Replacing Mini-Physical Interface Modules in the SRX320 Services Gateway The Mini-PIMs available on the SRX320 Services Gateway are not hot-swappable. You need to power off the device before removing or installing Mini-PIMs. For information on replacing Mini-PIMs, see...
Page 71
SEE ALSO SRX320 Services Gateway Interface Modules Overview | 23...
IN THIS SECTION Troubleshooting Resources for the SRX320 Services Gateway Overview | 73 Troubleshooting Chassis and Interface Alarm Messages on the SRX320 Services Gateway | 73 Troubleshooting the Power System on the SRX320 Services Gateway | 75 Using the RESET CONFIG Button | 75...
Page 74
Table 24: SRX320 Services Gateway Chassis Alarm Conditions and Corrective Actions Alarm Component Alarm Conditions Action Severity Boot media The services gateway boots If the internal flash memory fails at startup, the Amber from an alternate boot services gateway automatically boots itself from (minor) device.
Troubleshooting the Power System on the SRX320 Services Gateway The LEDs on the services gateway enable you to determine the performance and operation. The PWR LED, located on the front panel of the services gateway, indicates the different settings with respect to the power system.
The rescue configuration is a previously committed, valid configuration. You must have previously set the rescue configuration through the J-Web interface or the CLI. To press the RESET CONFIG button, insert a small probe (such as a straightened paper clip) into the pinhole on the front panel. By default, pressing and quickly releasing the RESET CONFIG button loads and commits the rescue configuration through the J-Web interface or the CLI.
Contacting Customer Support Once you have located the serial numbers of the device or component, you can return the device or component for repair or replacement. For this, you need to contact Juniper Networks Technical Assistance Center (JTAC). You can contact JTAC 24 hours a day, 7 days a week, using any of the following methods: On the Web: Using the Service Request Manager link at https://support.juniper.net/support/...
Returning a SRX320 Services Gateway Component to Juniper Networks To return an SRX320 Services Gateway or component to Juniper Networks for repair or replacement: 1. Determine the part number and serial number of the services gateway or component.
Mini-PIMs, depending on the placement of components on the Mini-PIM. Listing the SRX320 Services Gateway Component Details with the CLI Before contacting Juniper Networks to request an RMA, you must find the serial number on the SRX320 Services Gateway or component.
Required Tools and Parts for Packing the SRX320 Services Gateway To remove the components from the SRX320 Services Gateway or to remove the services gateway from a rack, you need the following tools and parts: Electrostatic bag or antistatic mat for each component Electrostatic discharge (ESD) grounding wrist strap Flat-blade screwdriver, approximately 1/4 in.
12. Write the Return Materials Authorization (RMA) number on the exterior of the box to ensure proper tracking. Packing SRX320 Services Gateway Components for Shipment Follow these guidelines for packing and shipping individual components of the services gateway: When you return a component, make sure that it is adequately protected with packing materials and packed so that the pieces are prevented from moving around inside the carton.
Definitions of Safety Warning Levels The documentation uses the following levels of safety warnings (there are two Warning formats): NOTE: You might find this information helpful in a particular situation, or you might overlook this important information if it was not highlighted in a Note. CAUTION: You need to observe the specified guidelines to prevent minor injury or discomfort to you or severe damage to the device.
Page 87
WARNING: This symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Waarschuwing Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan veroorzaken.
Varning! Denna varningssymbol signalerar fara. Du befinner dig i en situation som kan leda till personskada. Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanligt förfarande för att förebygga skador. General Safety Guidelines and Warnings The following guidelines help ensure your safety and protect the device from damage.
Page 89
Some parts of the chassis, including AC and DC power supply surfaces, power supply unit handles, SFB card handles, and fan tray handles might become hot. The following label provides the warning of the hot surfaces on the chassis: Always ensure that all modules, power supplies, and cover panels are fully inserted and that the installation screws are fully tightened.
Page 91
WARNING: This unit is intended for installation in restricted access areas. A restricted access area is an area to which access can be gained only by service personnel through the use of a special tool, lock and key, or other means of security, and which is controlled by the authority responsible for the location.
Page 92
¡Atención! Esta unidad ha sido diseñada para instalarse en áreas de acceso restringido. Área de acceso restringido significa un área a la que solamente tiene acceso el personal de servicio mediante la utilización de una herramienta especial, cerradura con llave, o algún otro medio de seguridad, y que está...
Qualified Personnel Warning WARNING: Only trained and qualified personnel should install or replace the device. Waarschuwing Installatie en reparaties mogen uitsluitend door getraind en bevoegd personeel uitgevoerd worden. Varoitus Ainoastaan koulutettu ja pätevä henkilökunta saa asentaa tai vaihtaa tämän laitteen. Attention Tout installation ou remplacement de l'appareil doit être réalisé...
Page 94
Always use an ESD wrist strap when you are handling components that are subject to ESD damage, and make sure that it is in direct contact with your skin. If a grounding strap is not available, hold the component in its antistatic bag (see Figure 23 on page in one hand and touch the exposed, bare metal of the device with the other hand immediately before inserting the component into the device.
In addition, you should establish procedures to protect your equipment in the event of a fire emergency. Juniper Networks products should be installed in an environment suitable for electronic equipment. We recommend that fire suppression equipment be available in the event of a fire in the vicinity of the equipment and that all local fire, safety, and electrical codes and ordinances be observed when you install and operate your equipment.
To keep warranties effective, do not use a dry chemical fire extinguisher to control a fire at or near a Juniper Networks device. If a dry chemical fire extinguisher is used, the unit is no longer eligible for coverage under a service agreement.
WARNING: Unterminated optical connectors can emit invisible laser radiation. The lens in the human eye focuses all the laser power on the retina, so focusing the eye directly on a laser source—even a low-power laser—could permanently damage the eye. Class 1 Laser Product Warning WARNING: Class 1 laser product.
Class 1 LED Product Warning WARNING: Class 1 LED product. Waarschuwing Klasse 1 LED-product. Varoitus Luokan 1 valodiodituote. Attention Alarme de produit LED Class I. Warnung Class 1 LED-Produktwarnung. Avvertenza Avvertenza prodotto LED di Classe 1. Advarsel LED-produkt i klasse 1. Aviso Produto de classe 1 com LED.
Laser Beam Warning WARNING: Do not stare into the laser beam or view it directly with optical instruments. Waarschuwing Niet in de straal staren of hem rechtstreeks bekijken met optische instrumenten. Varoitus Älä katso säteeseen äläkä tarkastele sitä suoraan optisen laitteen avulla. Attention Ne pas fixer le faisceau des yeux, ni l'observer directement à...
Radiation from Open Port Apertures Warning WARNING: Because invisible radiation might be emitted from the aperture of the port when no fiber cable is connected, avoid exposure to radiation and do not stare into open apertures. Waarschuwing Aangezien onzichtbare straling vanuit de opening van de poort kan komen als er geen fiberkabel aangesloten is, dient blootstelling aan straling en het kijken in open openingen vermeden te worden.
Maintenance and Operational Safety Guidelines and Warnings IN THIS SECTION Battery Handling Warning | 102 Jewelry Removal Warning | 103 Lightning Activity Warning | 105 Operating Temperature Warning | 106 Product Disposal Warning | 108 While performing the maintenance activities for devices, observe the following guidelines and warnings:...
Battery Handling Warning WARNING: Replacing a battery incorrectly might result in an explosion. Replace a battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions. Waarschuwing Er is ontploffingsgevaar als de batterij verkeerd vervangen wordt. Vervang de batterij slechts met hetzelfde of een equivalent type dat door de fabrikant aanbevolen is.
Page 104
WARNING: Before working on equipment that is connected to power lines, remove jewelry, including rings, necklaces, and watches. Metal objects heat up when connected to power and ground and can cause serious burns or can be welded to the terminals. Waarschuwing Alvorens aan apparatuur te werken die met elektrische leidingen is verbonden, sieraden (inclusief ringen, kettingen en horloges) verwijderen.
se conectan a la alimentación y a tierra, lo que puede ocasionar quemaduras graves o que los objetos metálicos queden soldados a los bornes. Varning! Tag av alla smycken (inklusive ringar, halsband och armbandsur) innan du arbetar på utrustning som är kopplad till kraftledningar. Metallobjekt hettas upp när de kopplas ihop med ström och jord och kan förorsaka allvarliga brännskador;...
Page 107
40° C. Para evitar a restrição à circulação de ar, deixe pelo menos um espaço de 15,2 cm à volta das aberturas de ventilação. ¡Atención! Para impedir que un encaminador de la serie Juniper Networks switch se recaliente, no lo haga funcionar en un área en la que se supere la temperatura ambiente máxima recomendada de 40°...
Varning! Förhindra att en Juniper Networks switch överhettas genom att inte använda den i ett område där den maximalt rekommenderade omgivningstemperaturen på 40° C överskrids. Förhindra att luftcirkulationen inskränks genom att se till att det finns fritt utrymme på minst 15,2 cm omkring ventilationsöppningarna.
Action to Take After an Electrical Accident If an electrical accident results in an injury, take the following actions in this order: 1. Use caution. Be aware of potentially hazardous conditions that could cause further injury. 2. Disconnect power from the device. 3.
Action to Take After an Electrical Accident | 109 SRX320 Services Gateway Agency Approvals The services gateway complies with the following standards: Safety CAN/CSA-C22.2 No.60950-1 (2007) Information Technology Equipment UL 60950-1 (2nd Ed.) Information Technology Equipment EN 60950-1 (2006+ A11:2010) Information Technology Equipment - Safety...
Reduction of Hazardous Substances (ROHS) 6 Telco Common Language Equipment Identifier (CLEI) code RELATED DOCUMENTATION SRX320 Services Gateway Acoustic Noise Compliance Statements | 111 SRX320 Services Gateway EMC Requirements | 112 SRX320 Services Gateway Acoustic Noise Compliance Statements The maximum emitted sound pressure level is 70 dB(A) or less per EN ISO 7779.
SRX320 Services Gateway EMC Requirements Canada This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. European Community This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.