EPSON AcuLaser C2000 / AcuLaser C1000

4.2.25 Rack Motor Assy.

4.2.25.1 Power Switch Removal

1. Remove the Rear Controller Cover. (See "Rear Controller Cover Removal"
on page -145.)
2. Remove the Rear Cover. (See "Rear Cover Removal" on page -146.)
3. Remove the Rear Right Cover. (See "Rear Right Cover Removal" on
page -146.)
4. Remove 2 screws securing the Power Switch.
Figure 4-64. Power Switch
Disassembly and Assembly

4.2.25.2 Rack Motor Assy. Removal

1. Remove 2 screws securing the power fan installation plate to the printer
and remove the power fan.
2. Remove the power switch. (See "Power Switch Removal" on page -175.)
3. Remove 1 connector and 2 screws of Rack Motor Assy.
4. Remove Rack Motor Assy.
Figure 4-65. Rack Motor Assy. Removal