Engine Related Service Call Error Troubleshooting - Epson ACULASER COLOR 2000 Service Manual

A4 color laser printer
Hide thumbs Also See for ACULASER COLOR 2000:
Table of Contents

Advertisement

EPSON AcuLaser C2000 / AcuLaser C1000
Table 3-7. Engine Related Service Call Error
(AcuLaser C1000) (continued)
Error Code
6032
(2-32) Fuser roller gap control error
6033
(2-33) Transparency detection sensor error
6034
(2-34) Multiple manual feeder pusher error
6041
(2-41) Main unit memory counter error
6042
(2-42) Main unit memory data error
6043
(2-43) Main unit memory access error
6044
(2-44) Main unit memory installation error
6998
Engine communication error
Troubleshooting
Description
Printer Message

3.2.5.2 Engine Related Service Call Error Troubleshooting

Fusing Unit is Abnormal
No.
Check Item
Check the connection between
1
the fusing unit and connector.
Does heater lamp 1 (H1) light on
2
when turning the printer on?
Does heater lamp 2 (H2) light on
3
when turning the printer on?
Others
The abnormal fusing unit is caused by abnormal heat roller temperature up,
abnormal heat roller low temperature, abnormal heat roller high temperature,
abnormal heat roller thermistor, abnormal pressure roller temperature up,
abnormal pressure roller low temperature, abnormal temperature high
temperature, abnormal pressure roller thermistor.
1. When the temperature of the heat roller does not go up by the specified
value for 22 to 40 seconds after warm-up is started. Same can be said for
the pressure roller temperature.
2. When the temperature of the pressure roller does not reach 80
seconds after warm-up. It is detected as abnormal pressure roller heat up.
3. When the temperature of the heat roller does not reach does not reach
170
C within 140 seconds after the temperature of pressure roller reaches
°
80
C after warm-boots, it detects as abnormal heat roller temperature up.
°
4. When the temperature of the pressure roller does not reach 130
70 seconds after the temperature of the heat roller becomes more than
170
C AND when the temperature of the pressure roller does not reach
°
150
C within 140 seconds, it detects as the abnormal pressure roller
°
temperature up.
Revision E
Solution
Remove the fusing unit and install it
-
again.
No
Replace the fusing unit.
No
Replace the fusing unit.
Replace PU1 (power board).
Replace PWB-A.
C for 90
°
C within
°
125

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aculaser color 1000

Table of Contents